Note
Arming the system to "Level 3
with No Delay" or arming to
Level 3 from a keychain touch-
pad or hand held touchpad
overrides the Auto Stay Arming
feature.
Note
The panel clock must be set
with the correct time for accu-
rate supervisory time reporting.
See "Time (1st Tier)" on
page 23.
Note
The first trip of a sensor will be
a local alarm (doesn't call in),
the second trip must be a dif-
ferent sensor within 4 minutes
of the first trip.
18

QUICK ARM (2nd Tier)

(Default = off)
Quick Arm allows system arming without using an access code. When Quick Arm is on, the
system arming level can be increased without entering an access code.
A valid access code is still required to disarm the system.
¾
To turn quick arm on or off:
Š Press # to turn on or off.

QUICK EXIT (2nd Tier)

(Default = on, UL installations = off)
This setting determines whether or not users can open and close a standard entry/exit door
without causing an alarm (while the system is armed).
When Quick Exit is on and the system is armed, pressing Quick Exit starts a 2 minute timer.
During the two minutes exit or entry is allowed through a standard entry/exit door (sensor
group 10). You may open and close the entry/exit door as many times as necessary within the
two minutes.
When this feature is turned off, the system must be disarmed if a protected door is opened.
¾
To turn Quick Exit on or off:
Š Press # to turn on or off.

AUTO STAY ARM (2nd Tier)

(Default = on)
This setting determines whether or not the system automatically arms only doors and windows
if the user arms the system without exiting the premises. This can help prevent accidental
alarms by deactivating interior motion sensors during occupied arming periods.
When this feature is on and the system is armed, the display counts down the exit delay time. If
the exit delay time expires with no group 10 sensor activation, the system automatically arms
to Level 2, doors and windows.
¾
To turn Auto Stay Arm on or off:
Š Press # to turn on or off.

SUPV TIME (2nd Tier)

(Default = from 1:00 AM to 3:59 AM, Parameters = 12:00 AM - 11:59 PM)
Supervisory Time determines what time of day the panel sends supervisory, low battery, and
auto phone test reports to the central station.
¾
To set the Supervisory Time:
Š Press #, enter desire time, use scroll keys to select am or pm, and then press #.

ALARM VERIFY (2nd Tier)

(Default = off, UL Listed installations = set to off)
This setting determines whether the panel reports to the central monitoring station after a single
sensor or zone trip (off) or waits for a second trip before reporting (on).
This setting affects sensors/zones in groups 10 through 20. If Alarm Verify is set to on, group
18 responds the same as group 17.
¾
To turn Alarm Verify on or off:
Š Press # to turn on or off.