Information - Konica Minolta CA-410 Series Instruction Manual

Display color analyzer pc software ca-s40 ver. 1.3 probe+
Hide thumbs Also See for CA-410 Series:
Table of Contents

Advertisement

Information

Updated information is provided.
Message
New CA device is connected.
New probe is connected.
Another PC Software for Color Analyzer
instance is already running.
Re-connection to device in progress...
0-CAL in progress. . .
Measurement is cancelled.
RGB+W Matrix is successfully applied.
Single-point is successfully applied.
Set Target is successfully applied.
ID and Comment are successfully applied.
Calibration measurement failed.
Target measurement failed.
Read data in progress. . .
Saving data for Log No. [No.]...
No data selected.
No available data.
Cannot delete measurement data.
No data to save.
Gamma measurement cancelled.
Interval measurement in progress...
Package measurement in progress...
JEITA flicker measurement in progress...
Reading memory...
Please check the boxes corresponding to
the colors to be measured.
List display color, error code: List color displayed on data processor, error code
List display color
White
Blue
1:Different from cal
Probe
Blue
2:Δt out of range
Blue
3:Δt out of range
Blue
4:Below
measurement range
Blue
5:Out of
measurement range
This message appears when a different device is connected after the USB
connection has been disconnected or when there is a device switchover from
the Settings screen.
This message appears when a separate probe is selected while a data
processor is connected.
This message indicates a repeated launch attempt. Multiple copies of the
software cannot run simultaneously.
Re-connection to the device is in progress. Wait without unplugging the USB
flash drive.
Zero calibration is in progress.
The measurement has been canceled.
RGB+W matrix calibration has been successfully completed.
Single-point calibration has been successfully completed.
Color difference target has been successfully set.
ID and comment have been successfully set.
Measurement for calibration failed.
Measurement for setting the target failed.
Data processor data is being read.
Log data is being saved.
Data has not been selected.
There is no operable data.
Measurement data cannot be deleted.
There is no data to be saved.
Gamma measurement has been canceled.
Interval measurement is in progress.
Package measurement is in progress.
JEITA measurement is in progress.
Memory is being read.
No color has been selected to be measured. Check the check boxes of the
colors to be measured.
Error Code
The probe(s) being used are different from when user calibration / target
setting and measurement was performed.
The temperature inside the probe has changed more than the specified
amount since zero calibration.
Error code 1 and error code 2 occurred at the same time.
Measurement is out of measurement range.
Error code 1 and error code 4 occurred at the same time.
Details
Meaning
76