Chroma Studio Force II 12 User Manual

Chroma Studio Force II 12 User Manual

Hide thumbs Also See for Studio Force II 12:

Advertisement

Quick Links

Chroma-Q
Studio Force II™ 12/ 48/ 72
Version 1.0 June 2018, Software Version 1.4
Part Number:
Model:

User Manual

(CHSF2V12, CHSF2V12LR, CHSF2V12W)
(CHSF2V48, CHSF2V48LR, CHSF2V48W)
(CHSF2V72, CHSF2V72LR, CHSF2V72W)
(652-1150, 652-1650, 652-1250)
(641-4000, 641-4100, 641-4500)
(641-5000, 641-5100, 641-5500)
®

Advertisement

Table of Contents
loading

Summary of Contents for Chroma Studio Force II 12

  • Page 1: User Manual

    Chroma-Q ® Studio Force II™ 12/ 48/ 72 User Manual Version 1.0 June 2018, Software Version 1.4 Part Number: (CHSF2V12, CHSF2V12LR, CHSF2V12W) (CHSF2V48, CHSF2V48LR, CHSF2V48W) (CHSF2V72, CHSF2V72LR, CHSF2V72W) Model: (652-1150, 652-1650, 652-1250) (641-4000, 641-4100, 641-4500) (641-5000, 641-5100, 641-5500)
  • Page 2: Warranty Statement

    Chroma-Q unless the Customer provides acceptable proof to Chroma-Q that the defect or damage was not caused by the above; (e) by modification, repair or service by anyone other than Chroma-Q, who has not applied for and been approved by...
  • Page 3 Suggestions of use shall not be taken as inducements to infringe any patent. Chroma-Q sole warranty is that the product will meet the sales specifications in effect at the time of shipment. Your exclusive remedy for breach of such warranty is limited to refund of purchase price or replacement of any product shown to be other than as warranted.
  • Page 4: Safety Information

    If you experience difficulties with any Chroma-Q products please contact your local dealer. If your local dealer is unable to help then please contact support@chroma-q.com. If you are having trouble finding what you are looking for on our website, then contact our Chroma-Q marketing department by sending an email to marketing@chroma-q.com.
  • Page 5: Protection From Electric Shock

    Use only the cables specified in this manual and on the Chroma-Q website at www.chroma-q.com to interconnect devices in the installation. If the specified cables are not long enough for an intended cable run, consult Chroma-Q for assistance in finding or creating a safe alternative solution. •...
  • Page 6 Contents www.chroma-q.com...
  • Page 7 www.chroma-q.com...
  • Page 8: Product Overview

    Product overview The Chroma-Q Studio Force II LED batten range is a powerful lineup of professional lighting industry. With up to ≈36,000/ Studio Force II 72, ≈24,000/ Studio Force II 48, ≈6,500/ Studio Force II 12 hot lumens output, these super bright fixtures are specifically designed for TV Broadcast and film applications but also performs particularly well in other situations demanding high quality tunable white light such as touring key lights, exhibitions, corporate events and theatre lighting.
  • Page 9: Unpacking The Units

    2 x SF II 72 4 x SF II 72 SF II 48 550W 3 x SF II 48 6 x SF II 48 SF II 12 150W 10 x SF II 12 20 x SF II 12 Table 3 (Fixtures in series) www.chroma-q.com...
  • Page 10 Studio Force II comes standard with a 22º X 22º beam angle optics. 2 additional lenses can be position in front the standard optics. The output beam angle with Border Lens is 43 x 43 and with CYC Lens , 80 . This can be seen in Figure 4 <<add proper reference for figure>>> www.chroma-q.com...
  • Page 11 ON and configure the fixture when it is not connected to the AC mains power. • Tap on Focus button to turn ON the fixture for 30 sec Figure 6 (Start-up Screen) www.chroma-q.com...
  • Page 12: Main Menu

    - appears when the fixture is set at a DMX controllable mode and is > > >DMX receiving a DMX signal from an external DMX source/ console. DMX > > > -appears when the fixture is set at Master and is outputting a DMX data signal. Table 4 (Data Signal Indicator) www.chroma-q.com...
  • Page 13 Control goes back to the Main menu screen and the new DMX start address will be displayed Tap on Escape anytime to cancel Mode Mode options Pixel Ordering Options Mode Select options Grouping options Apply Changes/Save Cancel / Go Back Figure 9 (Mode Options Screen) www.chroma-q.com...
  • Page 14 The default value for Kelvin and Hue parameters should be 50%. The crossfade parameter can be set to 16-bit for a more accurate crossfade when using very long transition. The DMX map is shown in Table 20 (DMX Map-CINE-Q-iKHRGBW). Figure 10 (CINE-Q CROSSFADE) www.chroma-q.com...
  • Page 15 **Extended Control Channel: An extra Control parameter can be enabled, it will be place as the last parameter of the fixture control mode. The Control channel allows for remotely control certain aspect of the fixture such as the fan speed, PWM frequency and more functions. www.chroma-q.com...
  • Page 16 RDM. HSi Legacy The option allows the new Studio force fixtures match the HSi pattern, with old Chroma-Q HSi mode enabled fixtures. With Legacy hue mode enabled, the Hue channel is from Blue to Blue (B→G→R→B).
  • Page 17 Selected Od/Ev Table 7 (SFII 72 DMX Grouping) Grouping: Studio Force II Flip: L→R Group Group Number(s) Selected Od/Ev Table 8 (SFII 48 DMX Grouping) Studio Force L→R Group Group Selected Number(s) Od/Ev Table 9 (SFII 12 DMX Grouping) www.chroma-q.com...
  • Page 18 Table 11 (SFII 72 Mode-Grouping DMX Values) Studio Force II Control Mode Cine-Q Cine-Q RGBW 16bit Grouping Od/Ev Table 12 (SFII 48 Mode-Grouping DMX Values) Studio Force II Control Mode Cine-Q Cine-Q RGBW 16bit Grouping Od/Ev Table 13 (SFII 12 Mode-Grouping DMX Values) www.chroma-q.com...
  • Page 19: Setup Menu

    The fixture can be set for light engine software upload/ upgrade through this screen. FW Version Displays current software version. Displays current DMX source – cable or wireless DMX Source Eng Temp Displays LIVE value for temperature of all the engines in fixture. Escape Exit the screen Table 14 (Setup Menu Options) www.chroma-q.com...
  • Page 20 Display screen menu can be rotated 180° (upside down) by tapping on this button. To set the orientation of the display, On the Main Menu screen, tap Setup Menu. On the Screen Setup screen, tap RotateDisp The display screen rotates by 180 degrees www.chroma-q.com...
  • Page 21 On the When DMX Lost screen, select and tap an output option, then tap Apply to save Note: If a Look is selected for playback when DMX is lost, the unit will playback the selected look on power up, as long as DMX is not present. www.chroma-q.com...
  • Page 22 If the Lock feature is enabled, touch and hold the lock icon for 5 seconds to unlock. Display Lock Icon Note: The Lock Icon turns green when pressed and held for 5 sec to unlock Figure 17 (Lock Feature Select Icon) www.chroma-q.com...
  • Page 23 To reset the fixture to the factory default settings, 1. On the Main Menu, tap Setup Menu 2. On the Setup screen, tap Reset 3. On the Reset Setting screen, tap Default 4. Press and hold Apply for 3 seconds to restore the factory default settings www.chroma-q.com...
  • Page 24 Upload Engine RECOMMENDED ONLY FOR FACTORY TRAINED PERSONNEL. LED Engine software can be uploaded to the fixture from the Chroma-Q Uploader II by accessing this menu. Refer to the Quick Start Guide of the Chroma-Q Uploader II. Link: http://www.chroma-q.com/support/quick-start/CHUSBLOADERII_Uploader-quickstartguide.pdf Software for the LED engines must be uploaded to the Studio Force II using the Chroma-Q Uploader II: In “Setup”, select “Upload Engines”...
  • Page 25: Look Store

    Press Store for 2 seconds to save the Look. “Look Stored” will be displayed on the screen to confirm. Multiple looks can be saved from Look (1-31). Playback button allows the user to check what look is at (1-31). www.chroma-q.com...
  • Page 26: Thermal Performance

    The airflow to and from the fan must not be constricted to maintain the maximum light output of the Studio Force II Troubleshooting Troubleshooting is a process of elimination. First, rule out the other field factors (i.e. bad connections, faulty cables and power supplies). For technical support and/or parts, please contact nearest Chroma-Q dealer. Symptom Possible Cause...
  • Page 27: Technical Specifications

    Up to 50,000 hours IP20 Operating 0ºC to 40ºC temperature: IP20 0ºC to 40ºC Approvals: CISPR 22:2006/EN55022:2006 & CISPR 24:1997/EN55024:1998 ICES- 0ºC to 40ºC 003:2004 & FCC Part 15 Subpart B:2007 CSA C22. No. 166-M1983:R2008 UL 1573:2003; UL 8750 www.chroma-q.com...
  • Page 28: Technical Drawings

    Technical Drawings Studio Force II 72 www.chroma-q.com...
  • Page 29 Studio Force II 48 www.chroma-q.com...
  • Page 30 Studio Force II 12 www.chroma-q.com...
  • Page 31 750 Hz 1,500 Hz 3,000 Hz Frequency 6,000 Hz 12,000 Hz 24,000 Hz Hold SETUP DMX Lost Look (Select) Disable Lock Enable Default User Reset Upload Eng Fw Version Cable DMX Source Wireless Eng Temp Select LOOKS Playback Store www.chroma-q.com...
  • Page 32 Channel 1 through 3 will repeat for each cell control according to the selected grouping mode Control parameter is only present when Extended mode is enabled Control parameter is always last, its position will change according the grouping mode. For example, in odd/even grouping mode, the control parameter would be on 7 www.chroma-q.com...
  • Page 33 Channel 1 through 3 will repeat for each cell control according to the selected grouping mode Control parameter is only present when Extended mode is enabled Control parameter is always last, its position will change according the grouping mode. For example, in odd/even grouping mode, the control parameter would be on 7 www.chroma-q.com...
  • Page 34 Channel 1 through 8 will repeat for each cell control according to the selected grouping mode Control parameter is only present when Extended mode is enabled Control parameter is always last, its position will change according the grouping mode. For example, in odd/even grouping mode, the control parameter would be on 17 www.chroma-q.com...
  • Page 35 Channel 1 through 9 will repeat for each cell control according to the selected grouping mode Control parameter is only present when Extended mode is enabled Control parameter is always last, its position will change according the grouping mode. For example, in odd/even grouping mode, the control parameter would be on 19 www.chroma-q.com...
  • Page 36 Studio Force II DMX map group modes Table 22 (DMX Map-Grouping Modes) Grouping Description Number of individual cells control mode Studio Force II 12 Studio Force II 48 Studio Force II 72 Entire fixture as one Group by 4 cells Odd/Even...

Table of Contents