Summary of Contents for Chroma Studio Force V Phosphor
Page 1
® Chroma-Q Studio Force™ V Phosphor User Manual Version 1.5 December 2014, Software Version 1.07 PN: 634-0500...
Page 2
(c) by operation outside the specifications contained in the user documentation; (d) by the use of spare parts not manufactured or sold by Chroma-Q or by the connection or integration of other equipment or software not approved by Chroma-Q unless the Customer provides acceptable proof to Chroma-Q that the defect or damage was not caused by the above;...
Page 3
Chroma-Q products are safe, effective, and fully satisfactory for the intended end use. Suggestions of use shall not be taken as inducements to infringe any patent. Chroma-Q sole warranty is that the product will meet the sales specifications in effect at the time of shipment.
Note: The maximum number of Studio Force V Phosphor fixtures running off a single power input cable is 10 at 120V AC or 20 at 240V AC. Please refer to ANSI and AWG standards for the maximum data and power cable lengths.
2.5 Control The Studio Force V Phosphor fixture can operate as a standalone unit or remotely controlled via ANSI E1.11 USITT DMX512- A protocol. The control functions can be accessed through the Touch Screen LCD display at the rear of the fixture.
Page 8
Command Description Button 0 – 9 Button numbers 0 to 9 for typing the new DMX start address. Apply Save the new DMX address. Escape Exit the screen without saving. www.chroma-q.com Studio Force V Phosphor User Manual V1.5 December 2014...
Page 9
The fixture is set as the Slave unit in stand-alone operation. The fixture set as slave unit follows the control modes set with the Master unit. Apply Save the settings. Escape Exit the screen without saving. www.chroma-q.com Studio Force V Phosphor User Manual V1.5 December 2014...
Page 10
Default – Factory default settings • User – User defined settings • Upload ENG The fixture can be set for software uploads through the Engine Upload screen. Escape Exit the screen without saving. www.chroma-q.com Studio Force V Phosphor User Manual V1.5 December 2014...
Page 11
Decrease intensity Level. Playback the look recorded on Rec1. Playback the look recorded on Rec2. Rec1 Save a look for M1. Rec2 Save a look for M2. Escape Exit the screen. www.chroma-q.com Studio Force V Phosphor User Manual V1.5 December 2014...
Page 12
Control Menu The control menu options are accessed through the touch-screen display at the rear of the Studio Force V Phosphor fixture. Main Menu The Main Menu displays the fixture name, control information (current assigned DMX address, Footprint, Mode), and the 4 command buttons: Change Add, Change Mode, Setup Menu and Manual.
Page 13
The screen goes back to the Main Menu showing Mode: Manual and fixture output goes to the manual settings set previously. Go back to the Main Menu and tap Manual to access the Manual Mode settings. Setup Menu www.chroma-q.com Studio Force V Phosphor User Manual V1.5 December 2014...
Page 14
In this menu, internal settings of the Studio Force V Phosphor can be re-configured. DMX Data Fan Speed RotateDisp Frequency DMX Lost Lock Reset Upload ENG DMX Data The screen shows the DMX start address, and the equivalent value for each of the DMX channels assigned to the fixture.
Page 15
3. On the Reset Setting screen, tap Default. 4. Press and hold Apply for 3 seconds to restore the factory default settings. The screen reboots to the opening screen and Main Menu. www.chroma-q.com Studio Force V Phosphor User Manual V1.5 December 2014...
Page 16
To play back the recorded setting, 1. On the Main Menu, tap Manual. 2. On the Manual Mode Setting screen, tap M1 or M2. The fixture goes to the previously recorded state. www.chroma-q.com Studio Force V Phosphor User Manual V1.5 December 2014...
1 DMX channel 2.7 Thermal Performance The Studio Force V Phosphor is built with an internal fan for internal cooling. The fixture output is automatically reduced when internal temperature exceeds 75ºC for automatic protection. This happens on rare and extreme conditions when ambient temperature is over 35ºC or the internal fans are blocked or damaged.
Symmetrical direct illumination 3200K - 5600K (+/- 200K) Color Gamut Performance enhanced Up to 91 Lamp Life L70 at 50,000 hours For exact measurements please refer to the line drawings below www.chroma-q.com Studio Force V Phosphor User Manual V1.5 December 2014...
Maintenance With care, the Studio Force V Phosphor fixtures require little maintenance. However, as the unit is likely to be used in a stage environment we recommend periodical internal inspection and cleaning of any resulting dust and cracked oil residue.