%4.5 Abnormal Output

4.5 ABNORMAL OUTPUT
4.5.01 Output Samples
Light Print on the Entire Page
Possible Causes:
1. Ribbon is "dried out". Replace the ribbon.
2. Head gap lever is in the incorrect position. Place the lever in correct position.
3. Paper is not within specification. Refer to Section One for paper specification.
Uneven Print Density
Possible Causes:
1. Printhead gap not within specification. Perform the printhead gap adjustment.
2. Defective platen. Replace the platen.
Smeared Print
Possible Causes:
1. Head gap lever is in the incorrect position. Place the lever in correct position.