Setup
3.4 Inputs and outputs
Digital input
If the input signal is activated with a logical signal (15 to 30 V DC) and the Polarity is set to
Active high level, the meter carries out an activity selected in the menu Input function:
● Reset totalizer
– Resets the totalizer when digital input is active.
● Start/Stop totalizer
– Stops the totalizer when digital input is active, then resumes when the input is inactive.
Note
Changing polarity
Changing the polarity triggers the signal input to execute the set functionality.
3.4.2

Channel 2 - output

3.4.2.1

Operation mode

Description
Operation mode - Sets the output functionality for channel operation.
Setting
Default
Related
Path
3.4.2.2

Active operation (read only)

Description
Shows application possibilities.
Setting
Default
Related
Path
70
Off; Current output
Off
Setup → Inputs and outputs → Channel 2 - output → Operation mode
Active operation not possible, use passive wiring; Active operation possible, hardware is
able to drive the current loop
Setup → Inputs and outputs → Channel 2 - output → Active operation
FST020 Function manual
Function Manual, 09/2017, A5E42949526-AA