Siemens FST020 Function Manual page 74

Sitrans f series ultrasonic flowmeters ip65 nema 4x
Table of Contents

Advertisement

Setup
3.4 Inputs and outputs
3.4.3.4.3 Loop current scale
Description
Sets current output scaling according to desired measurement range.
Format:
<Nominal range> (<lower fault current>) <lower saturation limit> to <upper saturation limit>
(<upper fault current>) [<Description>]
Setting
Default
Related
Path
3.4.3.4.4 Upper range value
Description
Sets value at 100% of measuring span and corresponds to a loop current of 20 mA.
Setting and Default are sensor specific, depending on the setting in Process value and
depending on the Units setting.
Setting
Default
Related
Path
3.4.3.4.5 Lower range value
Description
Sets value at 0% of measuring span and corresponds to a loop current of 0/4 mA.
Setting and Default are sensor specific, depending on the setting in Process value and
depending on the Units setting.
Setting
Default
72
4 to 20 mA (3.50) 3.8 to 20.5 (22.6) NAMUR
4 to 20 mA (3.75) 4.0 to 20.8 (22.6) US
4 to 20 mA (0.00) 4.0 to 20.5 (22.0)
4 to 20 mA (2.00) 4.0 to 24.0 (25.0)
0 to 20 mA (0.00) 0.0 to 20.5 (22.0)
0 to 20 mA (0.00) 0.0 to 24.0 (25.0)
4 to 20 mA (3.50) 3.8 to 20.5 (22.6) NAMUR
Setup → Inputs and outputs → Channel 2 -output → Current output → Loop current scale
-3682800.00 kg/h to +3682800.00 kg/h
3682800.00 kg/h
Setup → Inputs and outputs → Channel 2 - output → Current output → Upper range value
-3682800.00 kg/h to +3682800.00 kg/h
0.00 kg/h
FST020 Function manual
Function Manual, 09/2017, A5E42949526-AA