94 • vacon
I/Oterm
System Menu
I/Oterm
Application
Standard
Figure 7-10. Change of application
7.3.6.3

Copy parameters

The parameter copy function is used when the operator wants to copy one or all parameter groups from
one drive to another or to store parameter sets in the internal memory of the converter. All the parameter
groups are first uploaded to the keypad, then the keypad is connected to another drive and then the
parameter groups are downloaded to it (or possibly back to the same drive).
Before any parameters can successfully be copied from one drive to another the drive has to be stopped
when the parameters are downloaded to it:
The parameter copy menu (S6.3) embodies four functions:
Parameter sets (S6.3.1)
The Vacon NX_ AC drive features a possibility for the user to load back the factory default parameter
values and to store and load two customised parameter sets (all parameters included in the application).
On Parameter sets page (S6.3.1), push the Menu button right to enter the Edit menu . The text LoadFactDef
begins to blink and you can confirm the loading of factory defaults by pushing the Enter button . The drive
resets automatically.
Alternatively you can choose any other of the storing or loading functions with the Browser buttons .
Confirm with the Enter button . Wait until 'OK' appears on the display.
7
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
STOP
READY
S1 S11
STOP
READY
STOP
READY
I/O term
Application
Standard
STOP
READY
I/O term
Application
enter
Multi-step
CONTROL KEYPAD

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents