Vacon Nx_6 - Mains Voltage 525-690 V - Vacon NX_ 0003 5 User Manual

Nx series; nxs series; nxp series;
Table of Contents

Advertisement

20 • vacon
4.2.2
Vacon NX_6 – Mains voltage 525—690 V
High overload = Max current IS, 2 sec/20 sec, 150% overloadability, 1 min/10 min
Low overload =
All sizes are available as IP21/NEMA1 Sizes FR4 to FR10 are additionally available as IP54/NEMA12.
FR12 is available only as NXP.
Mains voltage 525-690 V, 50/60 Hz, 3~
AC drive
type
Low
Rated
10%
continuous
overload
current I
current
L
(A)
(A)
NX_ 0004 6
4.5
5.0
NX_ 0005 6
5.5
6.1
NX_ 0007 6
7.5
8.3
NX_ 0010 6
10
11.0
NX_ 0013 6
13.5
14.9
NX_ 0018 6
18
19.8
NX_ 0022 6
22
24.2
NX_ 0027 6
27
29.7
NX_ 0034 6
34
37
NX_ 0041 6
41
45
NX_ 0052 6
52
57
NX_ 0062 6
62
68
NX_ 0080 6
80
88
NX_ 0100 6
100
110
NX_ 0125 6
125
138
NX_ 0144 6
144
158
NX_ 0170 6
170
187
NX_ 0208 6
208
229
NX_ 0261 6
261
287
NX_ 0325 6
325
358
NX_ 0385 6
385
424
NX_ 0416 6
416
458
NX_ 0460 6
460
506
NX_ 0502 6
502
552
NX_ 0590 6
590
649
NXP 0650 6
650
715
NXP 0750 6
750
825
NXP 0820 6
820
902
Table 4-2. Power ratings and dimensions of Vacon NX_, supply voltage 525—690V.
Note: The rated currents in given ambient temperatures are achieved only when the switching frequency is equal to
or less than the factory default.
Note: The rated currents for FR10 to FR12 are valid at an ambient temperature of 104 F (except for 0416 6, 0590 6
and 0820 6: rated currents valid at an ambient temperature of 95 °F).
4
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
Following continuous operation at rated output current, 150 % rated output current (IH)
for 1 min, followed by a period of load current less than rated current, and of such
duration that the r.m.s output current, over the duty cycle, does not exceed rated
output current (IH)
Max current IS, 2 sec/20 sec, 110% overloadability, 1 min/10 min
Following continuous operation at rated output current, 110% rated output current (IL)
for 1 min, followed by a period of load current less than rated current, and of such
duration that the r.m.s output current, over the duty cycle, does not exceed rated
output current (IL)
Loadability
High
Rated
50%
Max
continuous
overload
current
current I
current
I
H
S
(A)
(A)
3.2
4.8
6.4
4.5
6.8
9.0
5.5
8.3
11.0
7.5
11.3
15.0
10
15.0
20.0
13.5
20.3
27
18
27.0
36
22
33.0
44
27
41
54
34
51
68
41
62
82
52
78
104
62
93
124
80
120
160
100
150
200
125
188
213
144
216
245
170
255
289
208
312
375
261
392
470
325
488
585
325
488
585
385
578
693
460
690
828
502
753
904
590
885
1062
650
975
1170
650
975
1170
Motor shaft power
690V supply
575V supply
10%
50%
10%
overload
overload
overload
104 °F
122 °F
104 °F
P(HP)
P(HP)
P(hp)
4
3
3.0
5.4
4
3.0
7.4
5.4
5.0
10
7.4
7.5
13
10
11
20
13
15
25
20
20
29.4
25
25
40
29.4
30
50
40
40
60
50
50
74
60
60
101
74
75
121
101
100
147
121
125
177
147
150
214
177
150
268
214
200
335
268
250
422
335
300
476
422
400
536
422
450
603
476
450
670
603
500
751
670
600
845
751
650
952
845
800
1072
845
800
TECHNICAL DATA
Dimensions and
weight
50%
Frame
WxHxD/kg
overload
(in/lb)
122 °F
P(hp)
2.0
FR6
7.7x20.4x9.3/40.8
3.0
FR6
7.7x20.4x9.3/40.8
3.0
FR6
7.7x20.4x9.3/40.8
5.0
FR6
7.7x20.4x9.3/40.8
7.5
FR6
7.7x20.4x9.3/40.8
11
FR6
7.7x20.4x9.3/40.8
15
FR6
7.7x20.4x9.3/40.8
20
FR6
7.7x20.4x9.3/40.8
25
FR6
7.7x20.4x9.3/40.8
30
FR7
9.3x23.3x10.1/77.2
40
FR7
9.3x23.3x10.1/77.2
50
FR8
11.5x29.8x13.5/128
60
FR8
11.5x29.8x13.5/128
75
FR8
11.5x29.8x13.5/128
100
FR9
18.9x45.3x14.3/322
125
FR9
18.9x45.3x14.3/322
150
FR9
18.9x45.3x14.3/322
150
FR9
18.9x45.3x14.3/322
200
FR10
23.4x79.4x23.7/749.6
250
FR10
23.4x79.4x23.7/749.6
300
FR10
23.4x79.4x23.7/749.6
300
FR10
23.4x79.4x23.7/749.6
400
FR11
31.3x79.4x23.7/882
450
FR11
31.3x79.4x23.7/882
500
FR11
31.3x79.4x23.7/1036
600
FR12
47.6x79.4x23.7/1323
650
FR12
47.6x79.4x23.7/1323
650
FR12
47.6x79.4x23.7/1323

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents