COMMISSIONING
112
PresetRPM
0x70
113
PresetTq
0x71
Table 6- 1. Monitoring Data Class – Instance Attributes
6.2

Setting DeviceNet parameters with the control keypad

If the control keypad is used in setting the parameters of the Vacon DeviceNet board, certain values to
appropriate parameters must be given in menu M7 (for locating the expander board menu see Vacon
NX User's Manual, Chapter 7).
Note! If you use the keypad for setting the parameters, make sure that the settings correspond to the
settings in the Master system.
Expander board menu (M7)
Expander board menu
The
connected to the control board and 2) to reach and edit the parameters associated with the expander
board.
Enter the following menu level (G#) with the
Browser buttons
slots A to E with the
line of the display you also see the number of parameter groups associated with the board.
Menu button right
If you still press the
two groups: Editable parameters and Monitored values. A further press on the
takes you to either of these groups.
DeviceNet parameters
To set the DeviceNet board parameters, enter the level P7.5.1.# from the
Give desired values to all DeviceNet parameters (see Figure 6-1 and Table 6-1).
Note: The DeviceNet cable must be connected before any parameters can be edited. See page 6.
READY
Expander boards
G5
G1
READY
Mac ID
63
Figure 6-1. Changing the DeviceNet board parameter values
24-hour support +358 (0)40 837 1150 • Email: vacon@vacon.com
Get_Attribute_Single,
Set_Attribute_Single
Get_Attribute_Single,
Set_Attribute_Single
makes it possible for the user 1) to see what expander boards are
Menu button right
to see what expander boards are connected. On the lowermost
once you will reach the parameter group level where there are
READY
E:NXOPTC7
G1
G2
READY
Mac ID
63
0
C7
Sets safe state speed reference (RPM) if
0
the Safe State Behaviour attribute
30000
specifies "Preset Speed/Direction"
Warning: Review the application for safe
operation before specifying a value for
this attribute.
Inverter will require external stop.
0
C7
Sets safe state torque reference (0,00%) if
0
the Safe State Behaviour attribute
10000
specifies "Preset Speed/Direction"
Warning: Review the application for safe
operation before specifying a value for
this attribute.
Inverter will require external stop.
. At this level, you can browse through
Parameters
READY
Parameters
P1
P4
CHANGE VALUE
CONFIRM CHANGE
enter
vacon • 15
Menu button right
group (G7.5.1).