Replacement Of Main Component; Replacement Of Battery Module - Pylontech PowerCube-X1 Operation Manual

Lithium-ion phosphate energy storage system
Hide thumbs Also See for PowerCube-X1:
Table of Contents

Advertisement

(Check through the
monitor or maintenance
software.)
11
Another failure

5.2 Replacement of main component

Danger: The PowerCube-X1 is a high voltage DC system, operated by qualified and authorized
person only.
Danger: Before replace the main component must shut off the maintenance battery string's
power. Must confirm the D+ and D- terminal are without power. The turn off progress refer
to chapter 3.6.5.

5.2.1 Replacement of Battery Module

5.2.1.1 Use the charger to charge the new battery module to full (SOC 100%); When adding a new
battery module to the system, please fully charge the existing system as well.
5.2.1.2 Shut off the whole battery string's power. Must confirm the D+ and D- terminal are without
power. The turn off progress refer to chapter 3.6.5.
5.2.1.3 Pull out the Plug of Power Cable +/-. Pull out the plug of
communication cable.
Danger: the power cables and plugs still have high voltage DC power from serial connected
battery modules (battery module can't be turned off), must be careful to handle the Power
plugs.
5.2.1.4 Dismantle the 4 screws of the battery module's front face.
Cell failure or electrical
board failure.
22 / 31
module. Or change this
battery module.
Can't find out failure point
or can't check. Please
contact with seller or sells
agent.
18BISV0101

Advertisement

Table of Contents
loading

Table of Contents