Summary of Contents for Pylontech Extra 2000

  • Page 1 Extra 2000 Lithium-Iron Phosphate Battery Backup Product Manual Information Version: 1.2...
  • Page 2 Rights reserved. The trademarks of Pylon Technologies Co., Ltd are The names and logos of products from Pylontech are exclusive belongs to Pylon Technologies Co., Ltd, proprietary marks or registered trademarks. Other products or company names mentioned in this manual may be belonging to trademarks of their respective owners or tradenames.
  • Page 3: Safety Instructions

    Introduction Manual Explains Extra 2000 (V1.2) lithium iron phosphate battery is external backup power module for 48V devices. Under normal mains power, the power supply provides energy for user equipment and charging the battery; when the power supply interrupted, the battery provides energy for equipment.
  • Page 4: Table Of Contents

    Catalogue Extra 2000 ........................1 Lithium Iron Phospha te Ba tte ry Back up ..............1 1 Information ........................1 1.1 Information ---------------------------------------------------------------------------------------- 1 1.2 Product Features -------------------------------------------------------------------------------- 1 2 Structure and Parameter ....................2 2.1 Equipment Structure ---------------------------------------------------------------------------- 2 2.1.1 Equipment Model ....................
  • Page 5 Catalogue of Diagrams Figure 2-1 Extra 2000 Front Interface Diagram ..............3 Figure 3-1 Schematic of Installation Process ..............9 Figure 3-2 Schematic Device Fixed to the Cabinet ............13 Figure 3-3 Multiple Batteries in Parallel Power Line Connection Diagram ..... 14 Figure 3-4 Connection Interface between Battery and Load Equipment of DC Backup 15 Figure 3-5 Battery and Switch Power Connection Diagram ...........
  • Page 6 Catalogue of Table Table 2-1 Extra 2000 Equipment Model ................2 Table 2-2 Definition of RS232 Port Pin ................3 Table 2-3 ADD Switch ....................... 4 Table 2-4 LED Indicators Instructions ................4 Table 2-5 Protection Function Parameters ............... 6 Table 2-6 Charging Parameters ..................
  • Page 7 Extra 2000 Lithium Iron Phosphate Battery Backup Manual Introduction 1.1 Introduction Extra 2000 lithium iron phosphate battery backup is new energy storage battery products developed and produced by Pylontech according to market demand, it can be used to provide reliable backup power for various types of communication operators of 48V power supply equipments.
  • Page 8: Extra 2000

     Small size and light weight, standard of 19-inch embedded design, comfortable installation and maintenance; Structure and Parameter 2.1 Equipment Structure 2.1.1 Equipment Model Table2-1 Extra 2000 Equipment Model Product Rated Rated Model Size Weight...
  • Page 9 Extra 2000 Lithium Iron Phosphate Battery Backup Manual Figure 2-1 Sketch of Extra 2000 Product Front Interface Interface Protocol Standard: YD/T 1363.3-2005 " Part 3: Front intelligent device protocol of Communications Authority (Station) Power Supply, Air-conditioning and Environment Centralized Monitoring and Management Systems". O FF Power Port (1) Power cord connection: the same function of two power interface in parallel.
  • Page 10 Extra 2000 Lithium Iron Phosphate Battery Backup Manual Veneer Sends, Computer Receives Land ADD Switch (5)  ADD Switch: 4 ADD switches, to definite different address code for each battery module when network cascade multiple battery, up to 8 addresses. The coding and description see "Table 2-3 ADD Switch." Table 2-3 ADD Switch Coded Bit Address...
  • Page 11: Battery Management System(Bms

    Extra 2000 Lithium Iron Phosphate Battery Backup Manual Normal ● ● ● ● ● ● Shut Down All off Normal Flash1 Indicates Standby Standby PACK Low Voltage Alarm Flash3 Directive the right side Normal Light indicator LED Based on capacity flashes (flash 2), Alarm Light Flash3 Charge others lighting Stop charging, ALM Protection...
  • Page 12: Current Protection Function

    Protection parameters see entry 5 of "Table 2-5 Protection function parameters". Charging Current Limit: To ensure the load equipment working, Extra 2000 product sets the maximum charge current limit value; see "Table 2-6 Charging Parameters." Discharging Current Limit To protect the load equipment working, Extra 2000 sets the maximum discharge current limit;...
  • Page 13: Charge Parameters

    Discharging 2.3 Charge Parameters When the device working, reasonable charge voltage you should set, recommended charge voltage range shown in Table 2-6. The Extra 2000 product sets the maximum charge current to protect the power supply and load equipments. Table 2-6 Charging Parameters...
  • Page 14: Installation And Configuration

    Extra 2000 Lithium Iron Phosphate Battery Backup Manual Installation and Configuration 3.1 Installation Preparation Safety Requirements Only those who have finished training and knowledge and fully grasp the power system personnel may install the system. During installation process, one must always observe the safety requirements listed below and local safety regulations. ...
  • Page 15: Environmental Requirements

    Extra 2000 Lithium Iron Phosphate Battery Backup Manual 3.1.1 Environmental Requirements Ambient Temperature: -10℃~+55℃ Relative Humidity:5%〜93% RH Altitude: Under 4000m Working environment: No conductive dust and corrosive gas 3.1.2 Tools and Information Hardware Tools and instruments are shown in Table 3-1: Pylon Technologies Co., Ltd. Confidential Proprietary...
  • Page 16: Technical Preparation

    Antistatic Wrist Ring Strippers Ties Technical Information "Project Exploration Station Report", "Extra 2000 lithium iron phosphate Standby Power User's Manual" and "installation and inspection reports". 3.1.3 Technical Preparation Electrical Interface Checking Connected directly to the battery device could be user equipments, switching power supply or other power equipments.
  • Page 17: Unpacking

    Extra 2000 Lithium Iron Phosphate Battery Backup Manual operating current of the battery-powered load devices must be less than the maximum discharge current related products in Table 2-7. Landing Checking  The collocation of landing line in engine room should be furnished ground radiation or flat, it requiring three separate parts: DC power distribution systems protection, power system working and lightning protection.
  • Page 18: Equiment Installation

    There are tabs and mounting accessories equipment box. Before the equipment fixed, install tabs on both sides of the device, and confirm screws are tightly connected. 2 Equipment Installation Extra 2000 products using 19-inch rack-mountable, it can be installed in the Pylon Technologies Co., Ltd. Confidential Proprietary...
  • Page 19 Extra 2000 Lithium Iron Phosphate Battery Backup Manual chassis designed with battery, and also be installed in the cabinet. Put device in parallel on the pallet rack, push it into the cabinet to make a very tight against between tab and the mounting bracket, tighten with screws and floating nuts, it must be ensure that all devices are secure.
  • Page 20 Please kip this step and go to Step 3 when using a single battery. When using multiple batteries in parallel, firstly parallel each station batteries with the power cord. Extra 2000 product has 2 power interfaces on left front panel device, power connector from top to bottom are negative and positive. The 2 interfaces have same function, when multiple batteries in parallel, using parallel power cable to connect each battery.
  • Page 21 Extra 2000 Lithium Iron Phosphate Battery Backup Manual DC backup power interface. Multiple load equipment: use a division multiple power cords and the power cord directly connected to each of the DC backup power load device interface. Figure 3-4 Connection Diagram Interface between Battery and Load Equipment of DC Backup Power (2) Connection of the Battery and Switch Power This installation method can be used when switching power supply to loads.
  • Page 22 Extra 2000 Lithium Iron Phosphate Battery Backup Manual Note:  Confirm the positive and negative of switching power supply before connecting, the red power wire to positive and black one to negative;  Before connecting, verify the charging parameters of interface switching power supply battery. Voltage and current should satisfy charging parameters in Table 2-6 Battery.
  • Page 23 Extra 2000 Lithium Iron Phosphate Battery Backup Manual 5 Communication Interface Connection If using the local network, put the specially equipped RS232 communication cable to connect the battery and computer serial RS232 interface. If multiple network cascade battery, connect the battery RS232 interface with ADD Address is 1. 6 Powering on Device After completing these steps, turn on power to the entire system to activate the battery, installation completed.
  • Page 24: Using, Maintenance And Troubleshooting

    Extra 2000 Lithium Iron Phosphate Battery Backup Manual Using, Maintenance and Troubleshooting 4.1 Alarm Description and Processing When protection start or failure, the ALM indicator on the front panel will alarm, through net management can query specific alarm class and take appropriate action. 4.1.1 The Alarm and Countermeasure Influence System Output Please follow Table 4-1 processing if output of the fault appears such as over-voltage, charge over-current, under-voltage protection, high-temp protection and other abnormalities.
  • Page 25: Common Fault Analysis And Solutions

    Extra 2000 Lithium Iron Phosphate Battery Backup Manual should inspect equipment according to prompt information, and determine the fault type and location, and take appropriate measures to ensure the system is in the best working condition, not to affect the system output. Phenomenon and countermeasures are shown in Table 4-2. Table 4-2 Secondary Alarm Category Alarm Indication...
  • Page 26 As a leading industry provider of lithium iron phosphate backup solutions, focus on this type of problems, Pylontech put forward integrated high performance service of backup power protection for operators without occupying extra room space.
  • Page 27 Lightning protection design Environmental Standard GB/T 2423 Note: “ ” means it has this function; “-” means no such The Authentication Level TUV,CE,CCC,TLC function; “ ” means that this function is optional. For more information please contact Pylon Technologies Co., Ltd. www.pylontech.com.cn...