Status Monitor/Local Control Module Description; Overview; Status Monitor Description - Cisco GS7000 Installation And Configuration Manual

Hub/node status monitor/local control module
Table of Contents

Advertisement

Chapter 1 Overview

Status Monitor/Local Control Module Description

Overview

A local control module and a status monitor are available for the Model GS7000
Hub/Node. A status monitor consists of a local control module with a transponder
core module installed in the housing. The same housing is used for both units.
The units perform the following functions:
Local Control Module - controls redundancy and forward segmentation, and
configures the modules
Status Monitor - adds remote status monitoring capability to the local control
module
Note: An existing local control module can be field upgraded to a status monitor
through adding a transponder core module. Refer to Model GS7000 Hub/Node Local
Control Module to Status Monitor Upgrade Instructions, part number 4031341, for
complete instructions.

Status Monitor Description

The status monitor is HMS compliant and provides node monitoring and control
capability at the cable plant's headend. The following node voltages and signals are
monitored and their status reported to the headend by the status monitor.
Receiver optical input level (all receivers)
Transmitter optical output level (all transmitters)
AC power presence and peak voltage (for split AC powering cases, AC
power from both sides of node housing is monitored)
DC voltages from both primary and redundant power supplies
Optical amplifier operating parameters
Optical switch operating parameters
Commands are sent from the headend to the status monitor. The status monitor
communicates serially with the RF amplifier module to control the optional forward
band redundancy switches on the forward configuration module, the reverse band 6
dB (wink) attenuators on the reverse amplifier PWB, and the reverse band on/off
switches on the reverse amplifier PWB.
Note: Configuration parameters for the transponder core module, such as IP
address, can be changed using the PC-based GS7000 ViewPort software.