entPhysicalDescr
The previous table lists valid equipment entries for entPhysicalDescr. However,
"GS7000 EDFA Broadcast 17.0 dBm" is just one of several possible entries for an
EDFA. All valid EDFA entries are listed in the following table.
entPhysicalDescr entries for the EDFA
GS7000 EDFA Broadcast 17.0 dBm
GS7000 EDFA Broadcast 20.0 dBm
GS7000 EDFA Broadcast 22.0 dBm
GS7000 EDFA GF 17.0dBm Low Gain
GS7000 EDFA GF 21.0dBm Low Gain
GS7000 EDFA GF 17.0dBm High Gain
GS7000 EDFA GF 21.0dBm High Gain
Modules, power supplies, and the SM/LCM all have a value of 12 for
entPhysicalContainedIn. The GS7000 Node, GS7000 Hub Node, and GS7000 Optical
Hub have a value of 0, since the hub/node is not contained in anything else.
entPhysicalClass is based on type. Power Supplies are powersupply(6). All other
equipment are module(9). The Hub/Node is stack(11).
entPhysicalParentRelPos is the same as the entPhysicalIndex, except for the
Hub/Node which has the value of 0.
entPhysicalName indicates the slot number for all modules, such as Slot 10, except
the Hub/Node, which holds a value of Hub or Node.
entPhysicalHardwareRev shows CCB for the EDFA and Optical Switch, LCM for
the Status Monitor/LCM, and na for all other modules, power supplies, and the
Hub/Node.
Both entPhysicalSoftwareRev and entPhysicalFirmwareRev display the active
software image from the module or na if the module does not have an image, such
as a power supply.
entPhysicalSerialNum comes directly from the module or LCM. If a serial number
is not available then na displays. Although this OID is Read-Write in the MIB, you
cannot change the serial number. It is assigned in the factory.