Elcometer 224 Operating Instructions Manual page 27

Digital profile gauge
Table of Contents

Advertisement

R
• COUNTED AVE: (
group (n=5). At the end of each group the gauge beeps and calculates the average for the group and
stores this average value, which is used for the statistical calculation. The individual readings in the
group are not stored. The value for n can be changed by pressing the n=5
3. Upper and lower Limits for the batch can be changed at any time once the batch has been created -
see "Set limits" on page 26.
4. Press OK to create the batch
Opening new batch in batch mode
Opening a new batch in batch mode duplicates (clones) an existing batch.
Cloning copies the following settings to the new batch:
Limits
Batch type
Zero setting
Note: Batch type cannot be changed once the cloned batch has been created. Limits and zero setting can
be changed after the batch has been created - see "Zeroing your gauge" on page 6 and "Set limits" on
page 26.
1. Open the batch which you want to clone and then press DATA>OPEN NEW BATCH.
Wait a few seconds while the batch is set up.
h.
The value for 'n' shown on the softkey can be any number between 2 and 255.
24
) - Readings are taken in preset groups, the default being 5 readings per
h
softkey.