AUMA AM 01.1 Operation Instructions Manual page 9

Hide thumbs Also See for AM 01.1:
Table of Contents

Advertisement

Operation instructions
Service conditions
Enclosure protection according
to EN 60 529
Corrosion protection
Finish coating
Colour
Ambient temperature
7)
Vibration resistance
according to IEC 60 068-2-6
Weight
Accessories
8)
Wall bracket
Other information
EU Directives
Reference documents
3) Only in combination with AM 01.1 and AM 02.1
6) For version in enclosure protection IP 68, a higher corrosion protection KS or KX is strongly recommended
7) Resistant to vibrations during start-up or for failures of the plant. However, a fatigue strength may not be derived from this
8) Cable length between actuator and AUMA MATIC max. 100 m. Not suitable for version with potentiometer in the actuator. Instead of the potentiometer, an RWG
has to be used in the actuator.
Standard:
IP 67 (when mounted)
6)
Options:
IP 68
3)
DS
Terminal compartment additionally sealed against interior (double
sealed)
Standard:
KN
Suitable for installation in industrial units, in water or power plants
with a low pollutant concentration
Optionen:
KS
Suitable for installation in occasionally or permanently aggressive
atmosphere with a moderate pollutant concentration
(e.g. wastewater treatment plants, chemical industry)
KX
Suitable for installation in extremely aggressive atmosphere with
high humidity and high pollutant concentration
KX-G
Same as KX, however aluminium-free version (outer parts)
Standard:
Two-component iron-mica combination
Option:
Special primer/special finish coat (customer's choice)
Standard:
Silver-grey (DB 701, similar to RAL 9007)
Option:
Other colours than standard colour are possible on request
AM 01.1/ AM 02.1:
Standard:
– 25 °C to + 70 °C
Options:
– 40 °C to + 70 °C, low temperature version
– 50 °C to + 70 °C, extreme low temperature version, incl. heating system
– 60 °C to + 70 °C, extreme low temperature version, incl. heating system
AMExB
Standard:
– 20 °C to + 40 °C
AMExC:
Standard:
– 20 °C to + 40 °C
Options:
– 40 °C to + 40 °C, low temperature version
– 50 °C to + 40 °C, extreme low temperature version, incl. heating system
1 g, for 10 to 200 Hz
(only for actuator with controls. Not valid in combination with gearboxes)
approx. 7 kg (with AUMA plug/ socket connector)
approx. 12 kg (with Ex-plug/ socket connector with terminal board)
AUMA MATIC mounted separately from the actuator, including plug/ socket connector.
Connecting cables on request..
Recommended for high ambient temperatures, difficult access, or in case of heavy
vibrations during service.
Electromagnetic Compatibility (EMC): (89/336/EEC)
Low Voltage Directive: (73/23/EEC)
Machinery Directive: (98/37/EC)
Product description "Actuator controls AUMA MATIC"
Dimension sheets "Multi-turn actuators/ part-turn actuators with integral controls AUMA
MATIC"
Actuator controls AUMA MATIC AM/ AMExB/ AMExC
Modbus
9

Advertisement

Table of Contents
loading

This manual is also suitable for:

Amexb 01.1Amexc 01.1Am 02.1