Renesas Emulation Probe M30850T2-EPB User Manual page 42

Emulation probe for m32c/80, 84, 85, 86 and 8a groups
Table of Contents

Advertisement

M30850T2-EPB User's Manual
Unscrew the screw of the oscillator circuit board of the PC7501 and replace it (see Figure 2.16).
Figure 2.16 Replacing oscillator circuit boards
Reinstall the upper cover once removed and secure the four screws of the PC7501.
When Removing the Upper Cover:
Always shut OFF power when removing the upper cover or changing the oscillator circuit board. Otherwise the
internal circuit may be damaged.
REJ10J1005-0200 Rev.2.00 April 1, 2007
The oscillator circuit board of the PC7501 is in the lower right corner of the
board.
Unscrew the screw securing the oscillator circuit board.
Lift off the oscillator circuit board.
Attach another oscillator circuit board to the connector.
Secure the new oscillator circuit board with the screw.
CAUTION
2. Setup
Page 42 of 98

Advertisement

Table of Contents
loading

Table of Contents