Pressure Gauge; Safety Relief Valves - Broaster 2400 Service Manual

Pressure fryer w/smarttouch
Hide thumbs Also See for 2400:
Table of Contents

Advertisement

PRESSURE GAUGE

Gauge indicates pressure within the cook-
ing well. Operating pressure is 12-14 PSI.
Replacement:
1.OPEN the pressure regulating valve then
the cover.
2. Unscrew gauge (15) from the elbow
(16).
3. Use teflon tape on the threads. Screw
new gauge onto the elbow.
SAFETY RELIEF VALVE
The safety relief valve opens in the event
pressure in the cooking well meets relief
pressure rating of the valve. DO NOT alter
or attempt to repair this valve. See PROPER
COVER OPERATION.
Keep away from safety
relief valve opening with-
out heat and steam protective apparel.
Escaping steam could cause serious
burns.
Replacement:
Replacement valve must
have a 15 PSI relief pres-
sure.
1.OPEN the pressure regulating valve then
direction of foot traffic areas.
5-9
broaster.com Manual #17280 1/15 Rev 6/15
the cover.
2. Unscrew valve (1) from the cover.
DO NOT install valve dis-
charge opening in the
3. Apply teflon tape to threads. Screw
new valve into the cover with valve
discharge opening facing the rear, at
an angle, away from foot traffic as
shown below.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

2400gh2400e

Table of Contents