2400GH Pressure Fryer:

TRANSFORMER (2400GH)

(This transformer not part of fryers manu-
factured for the European Union)
The transformer (12) supplies power to the
gas control valve.
1. See ACCESS FOR SEVICE.
4-3
broaster.com Manual #15460 8/02 Rev 6/15
2. Disconnect one wire from the primary
(black and white wires) side and sec-
ondary (yellow and blue wires) side of
the transformer.
3. Check between the two primary wires
with an ohmmeter. Meter should indi-
cate a closed circuit, If not, trans-
former is faulty.
4. Check between the two secondary
wires with an ohmmeter. Meter should
indicate a closed circuit. If not, trans-
former is faulty.