8- 1800Gh Main Burner System; Model 1800Gh Lighting Instructions; Gas Conversion; High Altitude - Broaster 1800 Service Manual

Pressure fryer w/smart touch control
Hide thumbs Also See for 1800:
Table of Contents

Advertisement

8 - 1800GH MAIN BURNER SYSTEM
MODEL 1800GH LIGHTING
INSTRUCTIONS
Start Up:
1. Turn cook/filter switch OFF.
2. See OIL LEVEL in the operation man-
ual.
3. Turn gas shut-off valve (1) ON. Wait
five minutes before turning gas control
ON.
4. Slide switch (2) on top of gas valve to
ON.
The Model 1800GH has
an intermittent pilot
burner. This type of pilot lights when the
controller calls for heat and goes out
when the controller is not calling for
heat.
5. To light pilot and main burners, turn
cook/filter switch to COOK.
8-1
broaster.com Manuals #17270 10/13 Rev 12/14
Shut Down:
1. Turn cook/filter switch OFF.
2. Turn gas valve switch (2) OFF.
3. Turn gas shut-off valve (1) OFF.

GAS CONVERSION

To convert from one type of gas to another,
five components must be changed: gas
valve, pilot burner orifice, main burner orifice
and gas data plate. Notify Broaster Com-
pany Service Department of a conversion in
writing.
Main Burner Orifice Sizes Up To 2000
Feet Above Sea Level:
Natural Gas: #24
Propane: #41

HIGH ALTITUDE

Standard gas units operate up to 2000 feet
above sea level. Installations above this
require a special main burner orifice. Con-
tact Broaster Company for orifice sizing.