Holding Register (Analogue Output)
Register Name
Addr
A/C Mode – Zone 1
28
A/C Mode – Zone 2
29
Set Tank Water Temperature
(signed)
30
Thermo-off Temperature
(signed)
Set Tank Water Temperature
31
Thermo-off Temperature
H/C Thermostat Target
32
Temperature – Zone 1 (signed)
H/C Thermostat Target
33
Temperature – Zone 1
H/C Thermostat Target
34
Temperature – Zone 2 (signed)
H/C Thermostat Target
35
Temperature – Zone 2
Modicon
Details
Address
0 = Heating Room Temp
1 = Heating Flow Temp
2 = Heating Heat Curve
40029
3 = Cooling Room Temp (not on 13K model)
4 = Cooling Flow Temp
5 = Floor Dryup
0 = Heating Room Temp
1 = Heating Flow Temp
2 = Heating Heat Curve
40030
3 = Cooling Room Temp (not on 13K model)
4 = Cooling Flow Temp
5 = Floor Dryup
Temperature value in ºC multiplied by 100.
(see note *)
40031
Temperature value in ºC multiplied by 100.
(see note *)
Temperature value in ºC multiplied by 100.
(see note **)
40032
Temperature value in ºC multiplied by 100.
(see note **)
Temperature value in ºC multiplied by 100.
40033
(see note *)
Temperature value in ºC multiplied by 100.
40034
(see note **)
Temperature value in ºC multiplied by 100.
40035
(see note *)
Temperature value in ºC multiplied by 100.
40036
(see note **)
Applicable Unit Type
#6
#6
33