0,55 ÷ 4 kW FREQUENCY CONVERTERS INSTRUCTION MANUAL TABLE OF CONTENTS APPLICATION ................................4 GENERAL FEATURES ............................... 4 FUNCTIONING ................................5 DECLARATION OF CONFORMITY ..........................5 MECHANICAL INSTALLATION ..........................5 TEST RUN ................................... 6 Cables and fuses ................................7 Main and Control Circuit Wiring ...........................
FREQUENCY CONVERTERS INSTRUCTION MANUAL Dear Customer! Thank you for having decided in favour of PROCON Ltd’s frequency converter. This Instruction Manual contains all information necessary for starting up and operating the frequency converter. Read this manual before installing the frequency converter.
0,55 ÷ 4 kW FREQUENCY CONVERTERS INSTRUCTION MANUAL FUNCTIONING The alternating voltage from the power line is rectified by a line diode bridge, then electrolytic capacitors smooth out the pulsating voltage. The intelligent IGBT end stage, driven with sinusoidal modulated pulses, delivers to the motor a voltage of variable amplitude and frequency.
0,55 ÷ 4 kW FREQUENCY CONVERTERS INSTRUCTION MANUAL TEST RUN In the course of the installation and test run the manufacturer’s attached wiring instructions and the instructions of the effective standards must be complied with. CAUTION Test run, maintenance, repair and component replacement in the frequency converter are allowed to be performed by authorized specialist only! WARNING ELECTRICAL SHOCK HAZARD...
At connecting the frequency converters use mains fuses and wires with cross-section as given in the table. Minimum Recomm. fuse value cable TYPE 0.75 ÷ 1 E3D 0.55 1 ÷ 1.5 E3D 0.75 1 ÷ 1.5 E3D 1.1 1.5 ÷ 2.5 E3D 1.5 1.5 ÷...
0,55 ÷ 4 kW FREQUENCY CONVERTERS INSTRUCTION MANUAL • Main and Control Circuit Wiring • Connecting the power line At connecting the power line comply with following safety measures: ▪ Use only circuit breakers that have been designed specifically for frequency converters. ▪...
0,55 ÷ 4 kW FREQUENCY CONVERTERS INSTRUCTION MANUAL PUTTING IN OPERATON THE FREQUENCY CONVERTER FOR THE FIRST TIME CAUTION Prior to put in operation the frequency converter read through thoroughly the description below! Follow all safety measures, warnings and instructions described in this manual! Heed the safety messages in this manual.
0,55 ÷ 4 kW FREQUENCY CONVERTERS INSTRUCTION MANUAL ASSIGNMENT AND CONNECTION OF THE E3D TERMINAL BLOCK 3 x 400VAC MOTOR LINE R BRAKE E3D frequency converter ÷ 2 10K 0÷10V 4÷ 0 2 mA (0÷ 0 2 mA) 500Ω min.
0,55 ÷ 4 kW FREQUENCY CONVERTERS INSTRUCTION MANUAL OPERATING THE CONVERTER The source of the reference signal can be: ▪ external or front panel potentiometer, ▪ 0÷10 V, ▪ 4÷20 mA (0÷20 mA), ▪ front panel controlling terminal, ▪ motor potentiometer The source of the logical control signals can be: ▪...
0,55 ÷ 4 kW FREQUENCY CONVERTERS INSTRUCTION MANUAL Submenu Description, further submenus Value, range Default setting Unit Programming the lower value and the function of Stop band 0V/mA 41.AnIn1 the reference signal (stop band, 0V/mA, 4mA). 0V/mA Analogue input 1 The stop band is active in control mode only (Reference signal) (indicated by flashing yellow LED).
Page 14
0,55 ÷ 4 kW FREQUENCY CONVERTERS INSTRUCTION MANUAL Submenu Description, further submenus Value, range Default setting Unit Selects zero set of the motor potentiometer None None 47. MP 0 reference signal. At switch-on Motor potentiom. On start reference signal At dir. change. zero set ...
0,55 ÷ 4 kW FREQUENCY CONVERTERS INSTRUCTION MANUAL • Parameter values in the display Values Short Actual frequency First row (fix) Motor current Second row Control reference signal The values can be Regulation reference signal scrolled with the Feedback signal ...
The necessary power is determined by the braking time and the duty factor. Frequency Resulting converter type resistance E3D 0.55 ÷ 1.1 ≥ 200 Ω E3D 1.5 ÷ 4 ≥ 100 Ω ▪ 100 W wire-wound ▪ 500 W wire-wound ▪...
0,55 ÷ 4 kW FREQUENCY CONVERTERS INSTRUCTION MANUAL PERIPHERAL EQUIPMENT SELECTION GUIDE ITEM 3 x 400 V line voltage Built-in mains noise suppressor IP20 cabinet ...
Page 20
PROCON Hajtástechnika Kft. H-1047 Budapest, Kisfaludy u. 4. Tel./fax: +36 1 370 9699 +36 1 379 5387 e-mail: procon@procon.hu info@procon.hu Internet: www.procon.hu XIII VIII XVII XVIII XXII XXIII Edition: April, 2018...