Omron CS1W-CT041 Operation Manual page 188

High-speed counter units
Hide thumbs Also See for CS1W-CT041:
Table of Contents

Advertisement

0)>4%"(+)*-?('5-0LMMNI0CMLO
Item
Counting
BCD:
Range
-8,388,608 to +8,388,607
Hexadecimal:
800000 to FFFFFF (-8,388,606 to –1) and
000000 to 7FFFFF (0 to 8,388,607)
Number of
2
Counters
Signals per
Phase A, B and Z
Counter
Count Signal
Line Driver
Levels
24 VDC
Input Signal
Phase Differential (multiplication x1, x2, x4)
Types
Up and Down
Pulse and Direction
Machine
0 to 15 (selectable by one rotary switch)
Number
Setting
Number of
1 Slot,
slots
10 words in IR-area (IR100 to IR 199 or IR
400 to IR459
100 words in DM-area (DM1000 to DM 2599)
Applicable
C200H, C200HS, C200HX, C200HG,
PLC's
C200HE, CS1
Current
400 mA at 5 VDC (Supplied from Backplane) 450 mA (CS1W-CT041), 360 mA (CS1W-CT021)
Consumption
Digital
16 Outputs consisting of:
Outputs
8 (external) Digital Outputs (NPN/PNP
selectable by DIP-switch)
8 Soft Outputs
Maximum switching capacity 16 to 80 mA at
5V to 24 VDC
Digital Inputs
4 (i.e. 2 per Counter)
Input Voltage 12 and 24 VDC
Maximum
75 kHz
Input
Frequency
Response
BCD: 1.2 ms max
time
Hexadecimal: 1.0 ms max
Output
Unit is per default in Range Mode and
Control Mode
Outputs are controlled according to the
Counter Value being within Range Limits
(Comparison Mode is not available)
Digital Input
Digital Inputs can not be configured to have
Functionality
different functionality
C200H-CT021
CS1W-CT021/CT041
Hexadecimal:
Circular Counter: 00000000 to FFFFFFFF (0 to
4,294,967,295)
Linear and Simple Counter: 80000000 to
7FFFFFFF (-2,147,483,648 to +2,147,483,647)
2 (CS1W-CT021), 4 (CS1W-CT041)
Phase A, B and Z
Line Driver
5, 12 and 24 VDC
Phase Differential (multiplication x1, x2, x4)
Up and Down
Pulse and Direction
0 to 92 (selectable by two rotary switches)
4 Slots,
40 words in CIO-area (CIO 2000 to CIO 2959)
400 words in DM-area (DM 20000 to DM 29599)
CS1
(at 5V via backplane)
32 Outputs consisting of:
4 (external) Digital Outputs (NPN/PNP selectable
in DM)
28 Soft Outputs
Maximum switching capacity 46 to 100 mA at 12
to 24 VDC
4 (can be assigned to multiple Counters, allowing
one Counter to be controlled by a maximum of 4
Digital Inputs)
Input Voltage 24 VDC
500 kHz
0.5 ms max
Unit can be configured for Range Mode or
Comparison Mode. In Comparison Mode the
Outputs are controlled according to the direction
in which the Counter Value crosses a
Comparison Value
Every Digital Input can be configured according
to one out of 17 available functions
Appendix A
$*&

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cs1w-ct021

Table of Contents