3&44)"'#.-@;A9J@;9EI@*+'"&$'()*+
4-5

Supported IOWR/IORD-Instructions

4-5-1

DM-data

Memory
Location
m
Output Control Mode
AND/OR Counter Output Patterns
m+1
Interrupt Task Offset (outputs)
m+2, m+3
Interrupt Mask Outputs
m+4
Interrupt Task Offset (inputs)
m+5
Interrupt Mask Digital Inputs
m+6
Physical Output NPN/PNP
Output State Control
m+7
Input Noise Filter Counters
m+8
Input Noise Filter Digital Inputs
m+9 to m+16
Output Pulse ON-delay and Pulse
Duration
m+17 to m+20
Digital Input Functionality
m+21, m+22
Predefined Output Pattern
m+23 to m+29
Not used
m+30
Counter Type
m+31
Signal Type
m+32
Z-reset Mode
Overflow/Underflow error-code
generation
m+33, m+34
Max. Count Value Circular/Linear
m+35, m+36
Min. Count Value Linear
m+37, m+38
Power On Preset Value
m+39
Time-Window (Rate Measurement)
m+40 to m+47
Rate-Range 0 Data
m+48 to m+55
Rate-Range 1 Data
m+56
Rate-Range 0 and 1 Enable Data
m+57, m+58
Range / Comparison Enable Data
m+59, m+60
Output (P)reset Set Pattern
m+61, m+62
Output (P)reset Reset Pattern
m+63
Hysteresis
m+64
# Ranges / # Comparison Values
m+65
Memory Area
m+66, m+67
Memory Address
m+68 to m+74
Not used
$%+
Item
General
Counter 'c' (c = 1, 2, 3, 4)
IOWR
IORD
N
N
---
N
N
---
N
N
---
Y
Y
0B
N
N
---
Y
Y
0B
N
N
---
N
N
---
N
N
---
N
N
---
N
N
---
N
N
---
N
N
---
---
---
---
N
N
---
N
N
---
Y
Y
cE
N
N
---
Y
Y
cC
Y
Y
cC
N
N
---
N
N
---
Y
Y
cF
Y
Y
cF
Y
Y
cB
Y
Y
cB
N
N
---
N
N
---
N
N
---
N
N
---
N
N
---
N
N
---
---
---
---
Section 4-5
Control Code
CC1
CC2
---
---
---
01
---
02
---
---
---
---
---
---
---
---
---
---
01
---
03
04
---
---
02
03
04
03
---
---
---
---
---
---
---
No. of
Words
---
---
---
2
---
1
---
---
---
---
---
---
---
---
1
---
2
2
---
---
8
8
1
2
---
---
---
---
---
---
---