5.4 RS422 Communication Port Connection

You set the jumper with a silkscreen side up.
RS422/RS232 converter is required to connect serial communication RS422 between Main Unit and PC
(Personal Computer). The converter used CNP200A.
- Connect RS422 TX [-], Yellow wire of Main Unit to White wire (Rx [-] port) of CNP200A converter.
- Connect RS422 TX [+], Grey wire of Main Unit to Red wire (Rx [+] port) of CNP200A converter.
- Connect RS422 Rx [-], Blue wire of Main Unit to Black wire (TX [-] port) of CNP200A converter.
- Connect RS422 Rx [+], Brown wire of Main Unit to blue wire (TX [+] port) of CNP200A converter.
- Plug in RS232 9-pin connector of CNP200A converter to COM1 or COM2 Port of PC.
- Install and run application software

6. Operation

6.1 Master Card Registration Mode

6.1.1 A Master Card Registration
The first card presented to the FGR006 after initialisation becomes the Master Card.
For master card registration mode refer to the "7.Operation Indication of Reader / Register" of
manual.
Note: A Master card cannot be used for access.
6.1.2 A Master Card Change
You can register Master Card again after initialisation of hardware.
CAUTION: If you initialise the hardware, all user data are deleted.
You can change the master card by using the application software.
Using the application software keeps the user data unchanged.
Please refer the FGR006 software manual for download master card.
6.1.3 A Master Card Function.
It is used as the key to change reader from normal mode to registration mode manually
For example)
In the Reader mode if you present the master card to the FGR006, it is changes it to registration mode.
In the Registration mode if you present the master card to the FGR006, it changes it to Reader mode.
(Therefore the master card cannot be used as an access card.)
mode.
101-091
FGR006 (FGR006EX) Wire
YELLOW
RS422-Tx[-]
GRAY
RS422-Tx[+]
BLUE
RS422-Rx[-]
BROWN
RS422-Rx[+]
15
CNP-200A Converter Wire
WHITE
Rx-
RED
Rx+
BLACK
Tx-
BLUE
Tx+