No.
Reset Communication Related
F6-08
Parameters
<4>
F6-10
Station Address
<5>
F6-11
Comm Speed
<5>
<1> To start and stop the drive with the CC-Link master device using serial communications, set b1-02 to "3". To
control the frequency reference of the drive via the master device, set b1-01 to "3".
<2> If set to 3, then the drive will continue to operate when a fault is detected. Take proper measures such as installing
an emergency stop switch.
<3> The drive default setting is 2.0 s, but this default setting will automatically be changed to 0.0 s when SI-C3/V is
connected.
<4> Software versions 1012 and later have F6-07 and F6-08 both set to 1.
<5> Power must be cycled in order for any setting changes to take affect.
<6> All station addresses must be unique. If set to 0, the L.ERR light will turn on and a Station Address Error (AEr)
will occur.
YASKAWA ELECTRIC TOBP C730600 22B V1000 Option CC-Link Installation Manual
Name
Determines which communication-related
parameters are set back to their original default
values when the drive is initialized.
0: Do not reset F6-
when the drive is initialized using parameter A1-03.
1: Rest F6-
drive is initialized using parameter A1-03.
Note: Setting this parameter does not affect
communication-related parameters.
0 to 64
<6>
0: 156 kbps
1: 625 kbps
2: 2.5 Mbps
3: 5 Mbps
4: 10 Mbps
6 CC-Link Option Drive Parameters
Description
and F7-
and F7-
parameters when the
Default
parameters
0
0
0
25