2.
Loosen the attachment screw and insert the terminal resistor described in the first
step between terminals DA and DB.
Note: Make sure that the option cover is put back on after wiring is complete.
Figure 14
YASKAWA ELECTRIC TOBP C730600 22B V1000 Option CC-Link Installation Manual
DA
DB
DG SLD SLD
Figure 15 Terminal Resistor Wiring