Battery Memory Set And Call Out - Skyrc Q200 Instruction Manual

Ac/dc quattro charger
Table of Contents

Advertisement

Battery Memory Set and Call Out

The charger can store up to 40 different charge/discharge profiles (each channel 10 sets)
for your convenience, and the stored profiles can be recalled quickly without having to go
through the setup process.
When you want to alter the parameter value in the program, press START/ENTER to
make it blink and then change the value with INC or DEC. The value will be stored by
pressing START/ENTER once.
Note: All following screens take 2S(7.4V) LiPo battery for example.
[ BATT MEMORY 1 ]
ENTER SET->
START/ENTER
BATT TYPE
LiPo
DEC INC
BATT VOLTS
7.4V ( 2S )
DEC INC
CHARGE CURRENT
4.9A
DEC INC
DSCH CURRENT
2.0A
DEC INC
DSCH VOLTAGE
3.0V/CELL
DEC INC
TVC=YOUR RISK
4.20V
DEC INC
SAVE PROGRAM
ENTER
START/ENTER
· 24
1. Battery Memory Set
Enter the battery memory program.
(10 different charge/discharge profiles can be stored in each channel).
Set the battery type (LiPo/LiFe/LiIon/LiHV/NiMH/NiCd/Pb).
Set the voltage and the number of cells (1S-6S).
Set the charge current (CH A/B:0.1-10.0A; CH C/D:0.1-5.0A).
Set the discharge current (0.1-2.0A).
Set the discharge cut-off voltage (3.0-3.3V/Cell).
Set the terminal charge voltage (4.18-4.25V).
Press ENTER to save the program.