Pb Lead-Acid Battery Program - Skyrc Q200 Instruction Manual

Ac/dc quattro charger
Table of Contents

Advertisement

Pb Lead-Acid Battery Program

Additional NiMH/NiCd Process Information:
During the NiMH/NiCd battery charging/discharging process the Q200 can display a
variety of information. Using the INC or DEC buttons, you can also view the following
information:
NiMH Sensitivity
D.Peak 4mV/CELL
Ext. Temp ----
Int. Temp 37 C
Safety Time
ON 200min
Pb Lead-Acid Battery Program
Pb (Lead-Acid):
BATT/PROGRAM
Pb BATT
Pb Charge Mode:
After selecting the correct battery type, use the INC or DEC button to change it to the
"CHARGE" mode.
Press the START button and the amp rate value will begin flashing. Use the INC or DEC
buttons to adjust the value to the desired charge rate. The amp rate should be set to
1/10th of capacity. For example, if you are charging a 20Ah battery the charge rate should
be set to 2A. Follow the instructions provided on your battery when setting the amp rate.
· 22
Delta Peak Voltage
Sensitivity setting
External*/ internal
temperature
Safety timer
setting
This program is only suitable for charging Pb (lead-acid)
batteries with nominal voltage ranging from 2 to 20V. Pb (lead-
acid) batteries are significantly different from NiMH/NiCd
batteries. Pb batteries can only deliver a low current in relation
to their capacity. The same restriction applies to the charging
process. Consequently, the optimum charge current can only be
1/10th of the capacity. A Pb battery cannot be used for fast
charging. Please follow the instructions provided by the battery
manufacturer.
The Q200 offers the following Pb charge modes: Charge and
Discharge.
In Power Voltage
12.56V
Temp Cut-off
50 C
Capacity Cut-Off
ON 5000mAh
Input Voltage
Temperature
cut-off
Capacity limit
setting
Q200

Advertisement

Table of Contents
loading

Table of Contents