Skyrc D100 V2 Instruction Manual

Skyrc D100 V2 Instruction Manual

Ac/dc dual balance charger, discharger / power supply
Hide thumbs Also See for D100 V2:

Advertisement

AC/DC Dual Balance Charger
V2
Discharger / Power Supply
Instruction Manual
[Version 1.0]

Advertisement

Table of Contents
loading

Summary of Contents for Skyrc D100 V2

  • Page 1 AC/DC Dual Balance Charger Discharger / Power Supply Instruction Manual [Version 1.0]...
  • Page 2: Table Of Contents

    Table of Contents INTRODUCTION SPECIAL FEATURES WARNING AND SAFETY NOTES PROGRAM FLOW CHART OPERATION POWER AND BATTERY CONNECTION OPERATING PROGRAM LITHIUM BATTERY PROGRAM (LIPO/LIFE/LILON/LIHV) NIMH/NICD BATTERY PROGRAM PB LEAD-ACID BATTERY PROGRAM DC POWER SUPPLY BATTERY MEMORY SET AND CALL OUT SYSTEM SETTING BATTERY VOLTAGE METER BATTERY RESISTANCE METER...
  • Page 3: Introduction

    Congratulations on your choice of SKYRC D100 V2 AC/DC Dual Balance Charger/Discharger/Power Supply. This unit is simple to use, but the operation of a sophisticated automatic charger such as SKYRC D100 V2 does require some knowledge on the part of the user. These operating instructions are designed to ensure that you quickly become familiar with its functions.
  • Page 4 Cells in Balance Charge Mode Main Menu Stop Any Charge Processes Switch from Channel A to B or Channel B to A DC Power LED Light DC Input: 11-18V Speaker System DC Output: 13.8V AC Input 100-240V · 02 D100 V2...
  • Page 5: Special Features

    Dual Input and Power Distribution The input of SKYRC D100 V2 is AC 100-240V and DC 11-18V. In DC mode, the power of each channel is 100W. Total power is 200W. In AC mode, it supports power distribution, for example, if both channel A and channel B are set to 40W, then, the DC power is 20W.
  • Page 6 Balancing Individual Cells Battery Discharging During the process of discharging, SKYRC D100 V2 can monitor and balance each cell of the battery individually. Error message will be indicated and the process will be ended automatically if the voltage of any single one cell is abnormal.
  • Page 7 If the temperature limit is reached, the process will be terminated. This function is only available by connecting optional temperature probe, which is not included in the package. Processing Time Limit: You can also limit the maximum process time to avoid any possible defect. D100 V2 05 ·...
  • Page 8: Warning And Safety Notes

    3.0-3.3V/cell 2.9-3.2V/cell 2.6-2.9V/cell 3.1-3.4V/cell Voltage Be very careful to choose the correct voltage for different types of battery otherwise you may cause damage to the batteries. Incorrect settings could cause the cells to fire or explode. · 06 D100 V2...
  • Page 9 Always refer to the manual by battery manufacturer about charging methods, recommended charging current and charging time. Especially, the lithium battery should be charged according the charging instruction provided by the manufacturer strictly. D100 V2 07 ·...
  • Page 10 This is a memory effect. It is said that NiCd and NiMH batteries are suffering from memory effect. NiCd has more memory effect than NiMH. · 08 D100 V2...
  • Page 11: Program Flow Chart

    [ BATT MEMORY 3 ] START Pb CHARGE ENTER CHARGER [ BATT MEMORY 3 ] SAVE PROGRAM SAVE PROGRAM Pb 4.0V (2S ) 3.3A 4.0V(2P) LOAD…… C:3.3A D:1.5A SAVE…. ENTER ENTER STARG/ENTER>3s Pb DISCHARGE 1.5A 4.0V(2P) D100 V2 09 ·...
  • Page 12: Operation

    If you have no request for LiPo Battery program, please press the BATT PROG/STOP button to enter BATT PROGRAM screen. · 10 D100 V2...
  • Page 13: Power And Battery Connection

    Power and Battery Connection 1. Connecting to power source There are two kinds of inputs for SKYRC D100 V2, DC 11-18V and AC 100-240V. AC 100-240V power source connection. 12V DC Battery / DC power supply connection. D100 V2 11 ·...
  • Page 14 "No balance cable detected, push enter to continue". The balance wire attached to the battery must be connected to the charger with the black wire aligned with the negative marking. Ensure correct polarity! 2) NiMH/NiCd or Pb Battery Connection NiMH · 12 D100 V2...
  • Page 15: Operating Program

    A and B is identical.. 1. Connection Connecting to power source There are two kinds of inputs for SKYRC D100 V2, DC 11-18V and AC 100-240V. A. Operating in AC mode SKYRC D100 V2 comes with built-in switching power supply. You can connect the AC power cord directly to the main AC socket.
  • Page 16 The balance wire attached to the battery must be connected to the charger with the black wire aligned with the negative marking. Take care to maintain correct polarity! (See the wiring diagram below.) This diagram shows the correct way to connect your battery to the SKYRC D100 V2 while charging. WARNING: Failure to connect as shown in this diagram will damage this charger.
  • Page 17: Lithium Battery Program (Lipo/Life/Lilon/Lihv)

    INC and DEC to change the value and press START/ ENTER to confirm your setting. START/ENTER Program Start LiPo BALANCE 2.0A 11.1V (3S) Press and hold START/ENTER for 3 seconds to start the program. START/ENTER > 3 Seconds D100 V2 15 ·...
  • Page 18 FINISH” and the charger will emit a ringing sound. The charger also displays battery voltage, charged capacity and elapsed time. [ Time: 00: 45: 32 ] 16.8V 2600mAh Program Stop During the charging process, press STOP to stop the charging process. · 16 D100 V2...
  • Page 19 Temperature probe needs to be connected to show external temperature. Int. Temp 37°C Temp Cut-Off Cut-off temperature.     Safety Timer Safety timer ON and duration of time in minutes. ON 200min Capacity Cut-Off Capacity cut-off ON and value of the set capacity limit. 5000mAh D100 V2 17 ·...
  • Page 20: Nimh/Nicd Battery Program

    NiMH/NiCd charge modes: Charge, Auto Charge, Discharge, Re-Peak and Cycle. Selecting the Battery Type: After powering on the D100 V2, press the INC or DEC button repeatedly until you reach the appropriate program for the battery type you wish to charge. For this example we have chosen the “NiMH BATT“...
  • Page 21 Follow the instructions provided on your battery when setting the voltage cut-off. The D100 V2 will stop discharging when the battery has reached the preset voltage cut-off. Press and hold the START button for 3 seconds to start discharging.
  • Page 22 A five-minute cool-down delay occurs after each re-peak charge. IN RE-PEAK MODE, THE D100 V2 USES THE CHARGE AMPERAGE AND VOLTAGE SETTINGS ENTERED IN CHARGE MODE.
  • Page 23 NiMH/NiCd Battery Program NiMH/NiCd Cycle Mode: The D100 V2 makes cycling of NiMH/NiCd batteries easy. The process of discharging and recharging (cycling) can be performed automatically with one simple step and will improve the performance of NiMH/NiCd batteries. We strongly recommend cycling any battery that has been discharged and stored for a period of time.
  • Page 24: Pb Lead-Acid Battery Program

    Pb Lead-Acid Battery Program Additional NiMH/NiCd Process Information: During the NiMH/NiCd battery charging/discharging process the D100 V2 can display a variety of information. Using the INC or DEC buttons, you can also view the following information: Delta Peak Voltage In Power Voltage...
  • Page 25 Additional Pb Process Information: During the Pb battery charging/discharging process the D100 V2 can display a variety of information. Using the INC or DEC buttons you can also view the following information:...
  • Page 26: Dc Power Supply

    DC Power Supply To use D100 V2 as a power supply, the user must connect it to AC power source. When the green LED on the back side turns on, then the user is free to use the power supply, the power of DC output is adjustable from 10W to 100W.
  • Page 27: Battery Memory Set And Call Out

    T V C = Y O U R R I S K ! Set the terminal voltage(4.18-4.25V). 4 . 2 0 V DEC INC S A V E P R O G R A M Press ENTER to save program. E N T E R START/ENTER D100 V2 25 ·...
  • Page 28 L O A D L i P o B A L A N C E C H G Press START/ENTER for 3 seconds to start the process. 4 . 9 A 7 . 4 V ( 2 S ) · 26 D100 V2...
  • Page 29: System Setting

    You can choose the temperature displayed T e m p e r a t u r e U n i t C e l s i u s by Celsius or Fahrenheit as you like. Fahrenheit D100 V2 27 ·...
  • Page 30 Press ENTER to load factory default setting. E n t e r It indicates the hardware and firmware V e r s i o n H W : 1 . 0 0 F W : 2 . 0 0 version. · 28 D100 V2...
  • Page 31: Battery Voltage Meter

    The screen indicate the total voltage, the highest M A I N 2 5 . 1 3 V H 4 . 2 0 0 V L 4 . 1 8 2 V voltage and the lowest voltage. D100 V2 29 ·...
  • Page 32: Battery Resistance Meter

    The screen indicate each cell's resistance. 0 0 6 m Ω The screen indicate the total resistance, the highest T A T A L :2 8 mΩ H :1 2 mΩ L :5 mΩ resistance and the lowest resistance. · 30 D100 V2...
  • Page 33: Warning And Error Message

    The battery voltage is higher than the maximum voltage B A T T E R Y W A S F U L L which the user sets when charging in balance mode. D100 V2 31 ·...
  • Page 34: Using The Charge Control Software "Charge Master

    “A” plug and the opposite end is terminated with “micro-B” plug which can connect to charger directly. You can control, monitor, operate two channels with one computer. The “Charge Master” can be download from www.skyrc.com. THESETCONTAINS 1. SKYRC D100 V2 Charger 2.
  • Page 35: Specification

    LiPo: 3.0-3.3V/cell LiIon: 2.9—3.2V/cell LiFe: 2.6-2.9V/cell LiHV: 3.1-3.4V/cell Pb: 1.8-2.0V/cell Discharge Wattage: 10Wx2 Balance Cells: 2-6 cells Memory: 10x2 Different Charge/Discharge Profiles Charge Method: CC/CV for Lithium Types and Lead (Pb) Batteries Delta-peak Sensitivity for NiMH/NiCd. D100 V2 33 ·...
  • Page 36: Conformity Declaration

    Conformity Declaration D100 V2 satisfy all relevant and mandatory CE directives and FCC Part 15 Subpart B: 2016. For CE directives: The product has been tested to meet the following technical standards: Electromagnetic Compatibility- Requirements for EN 55014-1:2006+ household appliances, electric tools and similar...
  • Page 37: Commonly Used Terms

    14.8 volts (4x3.7). If the nominal voltage of the battery is not printed on the battery's label, consult your battery manufacturer or supplier. Do not guess the rated voltage of battery. D100 V2 35 ·...
  • Page 38: Warranty And Service

    Liability exclusion This charger is designed and approved exclusively for use with the types of battery stated in this Instruction Manual. SkyRC accepts no liability of any kind if the charger is used for any purpose other than that stated.
  • Page 39 This content is subject to change. Latest version can be downloaded from www.skyrc.com If you have any question about this document, please contact SkyRC by sending a message to info@skyrc.cn All Rights Reserved. All specifications and figures are subject to change without notice. RoHS...

Table of Contents