System Setting

The charger will operate with default values for the essential user settings when it is
powered on for the first time. The screen displays the following system settings in
sequence and the user can change the parameter value on each screen.
When you want to change the parameter value, press START/ENTER to make it blink,
then change the value with INC or DEC. The value will be stored by pressing
START/ENTER once.
Preset V
ITEM
(
Safety Timer
ON
120Min
Capacity Cut-Off
ON
8000mAH
Temp Cut-Off
ON
50°C 122°F
Temperature Unit
Celsius
Rest Time
CHG>DCHG 10Min
· 26
alue)
SELECTION
OFF/
ON
1-720 Min
(
)
OFF/
ON
(
100-50000 mAh)
OFF/
ON
(20 C/68 F -
80 C/176 F
Celsius
Fahrenheit
1-60Min
DESCRIPTION
When you start a charge process, the
internal safety timer automatically starts
running at the same time. It is programmed
to prevent overcharging, if the battery
proves to be faulty or if the termination
circuit cannot detect the full battery. The
value of the safety timer should be
generous enough to allow full charging of
the battery.
This sets the maximum charge capacity
that will be supplied to the battery during
charge. If the delta peak voltage is not
detected for any reason or the safety timer
has not expired, this feature will
automatically stop the process at the
selected capacity value.
The battery's internal chemical reaction will
cause the temperature of the battery to
rise. If the temperature limit is reached, the
process will be terminated.
)
You can choose the temperature to be
displayed in Celsius or Fahrenheit.
Rest time allows the battery to cool down
between charging/discharging cycle.