User Voltage Calibration

During the manufacturing process every Q200 production unit gets tested and calibrated
after highest factory standards. Ambitious users who trust their own expensive equipment
more or who prefer their personal fluke to serve as reference have the possibility to adjust
the Q200 factory calibration by a few counts.
Note: We will explain channel D as the calibration procedure. The procedure for other
channels are identical.
1.
Have a 6S LiPo battery pack with stable voltage, preferably voltage range from 3.9V to
4.2V, at hand. With your digital multimeter, measure their voltages accurately with a
resolution of 3+ decimals, e.g. "3.918V, 3.939V, 3.928V, 3.908V, 3.923V, 3.908V".
Connect 6S LiPo battery balance wire to channel D. Select "BATT METER" menu and
2.
press "START" button. Then press and hold "START" button for 5 seconds to enter
calibrations screen.
Press "INC" button to adjust the voltage value from 3908 to 3918mV for the first cell.
3908 3954 3943mV
D
3923 3903 3923mV
Press "ENTER" button to confirm the first cell value. Repeat same procedure to adjust
other cells voltage. Press and hold the "START" button for 3 seconds to save
calibration date.
3918 3939 3928mV
D
3908 3923 3908mV
· 32
Press INC
3918 3954 3943mV
D
or DEC button
3923 3903 3923mV
Press and hold
Saving calibrate
START button
D
for 3S
Date......
3.92 3.94 3.93V
D
3.91 3.92 3.91V
Q200