Wacker Neuson DPU 4545 Operator's Manual page 33

Hide thumbs Also See for DPU 4545:
Table of Contents

Advertisement

Check water trap
Item
Designation
1
Plate cover
1. Dismantle the plate cover.
2. Loosen the hexagonal bolt 2-3 by revolutions.
3. Collect the escaping drops in a transparent container.
NOTICE
Since water is specifically heavier than diesel fuel, the water will exit first and then the fuel.
This can be seen by a clear separating line.
4. Once only fuel is escaping, tighten the hexagonal bolt.
5. Attach the plate cover.
Cleaning the machine
WARNING
Risk of fire and explosion when using flammable cleaning agents.
NOTICE
Penetrating water can damage the engine, electrical operator's controls or components of
the machine. Do not aim high pressure washer directly at air intake area and electrical
elements.
1. After cleaning, check the cable, hoses, utility lines and hardware for leaks, loose connections, chafe
marks and other damage.
2. Immediately eliminate detected damage.
Screwed connections
For the vibratory plates, the screwed connections must be regularly checked for a firm seat.
Check and replace V-belt and belt stabilizer
100_0202_mt_0008.fm
Do not clean the machine and elements with gasoline or other solvents.
Item
Designation
2
Hexagonal bolt
9 Maintenance