8 Operation and use
8.3.3
Commissioning the machine (electric start)
Item
Designation
1
Throttle lever
2
Decompression lever
1. Put the throttle lever in the full throttle position.
NOTICE
In extreme cold, actuate the decompression lever as well and push it up. In this position,
the decompression automation system audibly locks into place and the engine is ready to
start.
2. Insert the ignition switch key into the ignition lock and turn to the right. The charge control lamp will
illuminate and the acoustic signal will sound.
3. Turn ignition switch key to position ll. As soon as the engine starts, release the ignition switch key.
NOTICE
As soon as the engine starts, the vibration will begin.
4. Put the throttle lever in the idling position.
5. Allow the machine to warm up by idling for a few minutes.
26
Item
Designation
3
Ignition lock
4
Charge control lamp