8.3.2
Commissioning the machine in the cold (manual start)
NOTICE
For temperatures below -5 °C, generally freely turn the engine.
1
Item
Designation
1
Decompression lever
2
Lever for the oil pressure monitoring
1. Move the decompression lever to the center position.
2. Crank the engine with the starting crank counter-clockwise until it noticeably rotates more easily (10
- 20 crank revolutions).
3. Press the lever of the mechanical oil pressure monitoring for 15 seconds.
NOTICE
Remove dirt in the area of the metering device cover and remove the cover.
4. Fill motor oil in the metering device up to the upper rim.
5. Seat the cover and forcibly press it in.
NOTICE
Two fillings in succession are necessary.
6. Pull the decompression lever up until the detent.
7. Then start the engine immediately. See the chapter "Commissioning the machine (manual start)."
100_0202_op_0009.fm
3
2
Item
Designation
3
Metering device
8 Operation and use
25