Connection of cables for serial, contact signal lines and sub monitors of EC-
DIS
1. Unfasten the four bolts dashed circled below to remove the upper plate of the ca-
ble clamp.
2. Remove the spacers to pass the appropriate cables on the upper and lower
plates. The recommended cable entrances are shown as below.
3. Fasten the cables to the post part of the plates with cable ties (local supply).
Note: Be sure the vinyl sheath on the post.
Spacer
Serial cable
4. Pass the cables to the TB board 03P9648 and
03P9562 through the locking wire saddles (A, B and
C) in the figure shown right.
For the cables on the upper plate, use locking wire
saddles (A and B).
For the cables on the lower plate, use locking wire
saddles (A, B and C).
AMS (Serial)
AIS
ECDIS
GPS
RS-232C
(for brill control)
Cable tie
Ground termimal
Vinyl
sheath
Cable tie
Upper plate
AMS (Contact)
AD-10
(Antenna Unit)
HDG
LOG
Control Unit
Sub Monitor 1 of ECDIS
Sub Monitor 2 of ECDIS
Ground termimal
Vinyl
sheath
Cable tie
Lower plate
2. WIRING
Upper
plate
Lower
plate
Shield
Sub monitor cable
03P9648
( A )
03P9652
( B )
( C )
2-49