3. ADJUSTMENTS
[MONITOR TYPE]
The monitor type is preset at factory according to the ra-
dar type. For BB type radar, [MU-190•231] is set in ad-
vance. For other wide monitor, select [OTHER(W)].
Note: Select the monitor type correctly. If this menu is
set to [MU-270W] or [OTHER(W)] and no wide monitor is connected, the screen
blacks out. In this case, set DIP switch SW2 to ON, in order to change the monitor type
to MU-190/231.
[REMOTE MAINTENANCE]
Adjust setting for remote maintenance.
• [RMS PASSWORD]: Enter the password to open the
[MAINTENANCE PROFILE] and [SERIVCE GATE-
WAY] menus. For the password, contact your local
dealer.
• [MAINTENANCE PROFILE]: Available when [RMS
PASSWORD] is entered properly. Select [ON] to out-
put the equipment profile for remote maintenance.
• [SERIVCE GATEWAY]: Enter the IP address of the gateway for remote mainte-
nance.
[SYSTEM MONITOR]
• [DISP SYSTEM MONITOR]: Shows the system
monitor data through three pages. The following op-
erations are enabled:
F1 key: Goes to next page. After the last page, the system monitor window is not
shown.
F3 key: Saves the text data for the displayed page to an SD card.
F4 key: Saves the screen shot for the displayed page to an SD card.
[ANT CABLE]
Select the method of connection between the radar
sensor and the processor unit. [LAN] (LAN cable only)
or [LAN+COAXIAL] (LAN and coaxial cables). Select
[LAN+COAXIAL] when the optional LAN Signal Con-
verter is installed.