2. WIRING
13. Attach the appropriate WAGO connectors (pre-attached) to the appropriate ca-
bles, and then antenna and sub monitor cables to the RF-TB Board shown in the
following figure. For how to connect the WAGO connector, see "WAGO
connector" on page 2-5. For pin arrangement, see the interconnection diagram at
the back of this manual.
Note 1: Make sure to pass the cable through the specified locking wire saddle.
Note 2: A terminal opener is provided on the RF-TB Board.
Destination of Antenna cable:
Power line: TB801 through the locking wire saddle (A)
LAN cable: J821 through the locking wire saddles (A and B, two places)
Shield of power line: Screw (C)
Shield of LAN cable: Screw (D)
Note: For the antenna cable RW-9600/6895/4873, connect the crimp-on lug
(that binds unused wires) together with the shield of the power line.
Destination of sub monitor cable
Signal line: TB803 through the locking wire saddle (A), see the figure for the
"Destination of Antenna cable:"
Coaxial cable: TB804 (B)
Shield of signal line: Screw (C)