Batching Operation; 2-Speed Filling; Ingredient Filling - Avery Weigh-Tronix ZM303 User Instructions

Table of Contents

Advertisement

Indicator applications

3.5.3 Batching operation

Batching allows the indicator to control up to three motors, timers, augers, gates, etc.
using the three outputs for the purpose of making batches based on weight.
There are four types of batching operation:
Other parameters, that are set in a password protected menu, affect the batching
operation.
The bargraph will sequentially light up to show from 0 to 100% of the batch weight in
all types of batching except the independent setpoints.

3.5.4 2-Speed filling

2-Speed is for a single ingredient with a dual speed filling control (Fast/Slow), typically
a valve or hopper gate that can be full open, partially open or closed. When the fill starts
both SP1 and SP2 are turned on (outputs activated) which should set the dual speed
control to full open (Fast speed). When the Out 1 value is reached SP1 and Output 1
are turned off and this should set the dual speed control to partial open condition (Slow
speed). When Out 2 value is reached SP2 and Output 2 are turned off to close the
control device and complete the fill.
1.
2.
Example: To fill a product to 100 lb with the last 5 lb on slow fill: Out 1 should be set to
95 and Out 2 should be set to 100.
3.
4.

3.5.5 Ingredient filling

Ingredient filling is for batching up to 3 different ingredients controlled by Out 1, 2 and
3 values. If Out 2 value is 0 then it operates as a single ingredient filler. If Out 3 value
is 0 then it operates as 2 ingredient batcher.
1.
2.
3.
30
2-speed single ingredient
l
Ingredient filling (up to three ingredients)
l
Independent setpoints filling
l
Fill/discharge operation
l
Press SETUP or press and hold SELECT to access the setpoint editor.
Set Out1 to the fast fill value and Out 2 to the slow fill value.
To start or restart the 2-speed filling process, press START or F1.
To stop the filling process, press STOP or F1. (F1 toggles the process on and
off.)
Press SETUP or press and hold SELECT to access the setpoint editor.
Set Out1 to the ingredient 1 value, Out 2 to the ingredient 2 value and Out 3 to
the ingredient 3 value. See more details on Gross or Net weight batching in
Notes on batching on page
To start or restart the batching process, press START or F1.
69.
ZM303 Indicator User Instructions

Hide quick links:

Advertisement

Table of Contents
loading