3.3 Counting application
This section applies if Counting is active.
3.3.1 SELECT key default function
In the Counting application you can view the gross, net, tare, count and piece weight
display values by repeatedly pressing SELECT.
3.3.2 Special key functions
The following keys have an extra function in this application:
SAMPLE
F1
3.3.3 Sample operation
There are two types of sampling to select from; bulk and dribble. Either type is
selectable under a password protected menu.
Dribble sampling In this sampling method you can count out the specified number
Bulk sampling
Each method is described below.
3.3.4 Dribble sampling
With the dribble sampling method active, follow these steps to count.
1.
2.
3.
4a.
OR
ZM303 Indicator User Instructions
Press SAMPLE to perform the sample operation as described below in the
Dribble and Bulk sections.
Press and hold SAMPLE to perform the piece weight entry as described
below.
F1 works the same as the SAMPLE key when pressed.
of items onto the scale and when you are ready, press the
SAMPLE or F1 key and the scale starts to calculate piece weight
and then shows the count.
In this sampling method you place the specified number of items
on the scale all at once (in bulk) and the scale automatically starts
to calculate piece weight and then shows the count. This is the
default sampling method.
Press ZERO to zero the scale, if necessary.
Use a tare method to tare a container, if necessary. See
17.
Press SAMPLE or F1 ...
ZEroing is briefly displayed. This means the indicator is zeroing itself.
A numeric value (XX) is then displayed. This is the current sample size.
Accept the current sample size by pressing ZERO
3.3
Counting application
Net weighing on page
23