Accessories; Tzidc-210; Communication; Description - ABB TZIDC-200 Operating Instructions Manual

Electro-pneumatic positioner. for 4 ... 20 ma two-wire technology, hart, profibus pa, foundation fieldbus
Hide thumbs Also See for TZIDC-200:
Table of Contents

Advertisement

Specifications

9.1.10 Accessories

Mounting material
Attachment kit for linear actuators to DIN / IEC 534 / NAMUR
Attachment kit for part-turn actuators to VDI / VDE 3845
Attachment kit for integral mounting to control valves
Attachment kit for actuator-specific attachment upon request
Ex d cable entry
Cable gland and pipe plug approved for Ex d, securing adhesive
Pressure gauge block
With pressure gauges for supply and output pressure. Pressure
gauges with housing ø 28 mm (1.10 inch), with connection block in
aluminum, black with installation material for mounting on positioner
Filter regulator
All metal version in brass, varnished black, bronze filter element,
40 µm, with condensate drain.
Max. pre-pressure 16 bar (232 psi), output adjustable to 1.4 ... 6 bar
(20.31 ... 87.02 psi)
PC adapter for communication
LKS adapter f. plug conn. to positioner
FSK modem for HART communication
(see data sheet 63_6.71)
PC software for remote configuration and operation
DSV401 (SMART VISION) with DTM for TZIDC / TZIDC-200
available on CD ROM (see data sheet 63_1.20)
9.2

TZIDC-210

9.2.1

Communication

Profiles
Block types
Physical Layer
Transmission rate
Supply voltage
Max. permissible voltage
Power consumption
Current in the event of an
error
42
Profibus PA profile for process
devices
Electro-pneumatic actuators V3.0
1 AO Functional block
1 Transducer block
1 physical block
In compliance with IEC 61158-2
31.25 Kbit/s
Power feed from the PA bus,
9.0 ... 32.0 V DC
35 V DC
10.5 mA
15 mA (10.5 mA + 4.5 mA)
TZIDC-200, TZIDC-210, TZIDC-220
9.2.2

Description

Device name
PNO ID no.
Dev. ID
Bus address
9.2.3

Output

Range
Air capacity
Output function
Shut-off values
9.2.4

Travel

Ste
Rotation angle
Used range
25 ... 120°
rotary actuators, optionally 270°
25 ... 60°
linear actuators
Travel time
prolongation
Setting range
0 ... 200 seconds, separately for each
direction
9.2.5

Air supply

Instrument air
Supply pressure
IMPORTANT (NOTE)
Do not exceed the maximum operating pressure of the
actuator!
Air consumption
TZIDC-X10
0x0639
0X3200028xyz
Between 0 and 126, default address
126
0 ... 6 bar (0 ... 90 psi)
at 1.4 bar (20 psi) supply pressure
3
5.0 kg/h = 3.9 Nm
/h = 2.3 scfm
at supply pressure of 6 bar (90 psi)
3
13 kg/h = 10 Nm
/h = 6.0 scfm
For single or double-acting actuators,
air is vented from actuator or actuator
is blocked in case of (electrical) power
failure
end position 0 % = 0 ... 45 %
end position 100 % = 55 ... 100 %
free of oil, water and dust acc. to
DIN / ISO 8573-1
pollution and oil content according to
Class 3 (purity: max. particle size:
5 µm, max. particle density:
3
5 mg / m
; oil content: max.
3
concentration: 1 mg / m
; pressure
dew point: 10 K below operating
temperature
1.4 ... 6 bar (20 ... 90 psi)
< 0.1 kg/h / 0.05 scfm (independent
of supply pressure)
42/18-85-EN

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tzidc-220Tzidc-210

Table of Contents