Pulse Cancel Adj; Test Signal Level Adj - Panasonic AJ-SDX900P Service Manual

Camera/vtr, sdi output/pre-recording board
Hide thumbs Also See for AJ-SDX900P:
Table of Contents

Advertisement

2-8. Pulse Cancel Adj.

BOARD PRE AMP Board
TP103 (R), TP303 (G), TP503 (B)
TP
(PRE PROCESS Board)
ADJ.
EVR
F No.
-
MODE
CAM ON
M. EQ.
Oscilloscope
SPEC.
Level of center of noise = Level of BLK period
1.
Click the "7. Pulse Cancel Adjustment" of the camera
adjustment software.
2.
Connect a scope to TP103 (R-ch) and adjust the Slider
on the PC (EVR) so that the center of the noise of
signal period and BLK period are the same.
3.
Confirm that the level of horizontal blanking period is
not change during operating "GAIN" switch L, M, H.
If the level is changed, return to step 2 and adjust
again.
4.
Click ">>".
5.
Connect a scope to TP303 (G-ch) and adjust the Slider
on the PC (EVR) so that the center of the noise of
signal period and BLK period are the same.
6.
Confirm that the level of horizontal blanking period is
not change during operating "GAIN" switch L, M, H.
If the level is changed, return to step 5 and adjust
again.
7.
Click ">>".
8.
Connect a scope to TP503 (B-ch) and adjust the Slider
on the PC (EVR) so that the center of the noise of
signal period and BLK period are the same.
9.
Confirm that the level of horizontal blanking period is
not change during operating "GAIN" switch L, M, H.
If the level is changed, return to step 8 and adjust
again.
A
BLK
BLK
10. Connect a Vector Scope then set the gain to Max.
11. Confirm the black dot is on the origin of the Vector
Scope during operating "GAIN" switch L, M, H.
If the black dot is moved, return to step 2 and adjust
again.
12. Click ">>".
BLK
Center of the noise
Vector Scope (X5)

2-9. Test Signal Level Adj.

BOARD
PRE PROCESS Board
TP103 (R), TP303 (G), TP503 (B)
TP
(PRE PROCESS Board)
ADJ.
EVR
SIGNAL
Internal TEST Ramp Signal
MODE
-
M. EQ.
Oscilloscope
SPEC.
A = 1,000mVp-p
1.
Click the "8. Test Signal Level Adjustment" of the
camera adjustment software.
2.
Operate the "ABB" switch on the front of the Camera
and click "OK".
3.
Connect a scope to TP503 (B-ch) and adjust the Slider
on the PC so that the level "A" becomes 1,000mVp-p
±
10mV.
BLK
TP102: R
TP302: G
TP502: B
4.
Connect a scope to TP303 (G-ch) and adjust the Slider
on the PC so that the level "A" becomes 1,000mVp-p
±
10mV.
5.
Connect a scope to TP103 (R-ch) and adjust the Slider
on the PC so that the level "A" becomes 1,000mVp-p
±
10mV.
6.
Click ">>".
ELE-8
±
10mV
BLK
A

Advertisement

Chapters

Table of Contents
loading

This manual is also suitable for:

Aj-ya903gAj-sdx900eDvcpro 50Aj-d908mcAj-ya902g

Table of Contents