2-24. Cleaner Solenoid
Replacement & Adjustment
(Removal)
1.
Disconnect the connector (A) on the P.C.Board
(A). (Please refer item "7. Table of Connector"
about reference number of connector and name
of P.C.Board.)
Click this button
, then go to item "7. Table of
Connector".
2.
Unscrew the 2 screws (A) and remove the
Cleaner Solenoid Unit as shown in Figure 2-24-1.
3.
Unscrew the 2 screws (B) and remove the
Cleaner Solenoid as shown in Figure 2-24-1.
(Installation)
1.
Install the new Cleaner Solenoid follow the
removal steps in reverse order.
2.
After installation, perform the Cleaner Solenoid
Position adjustment.
Figure 2-24-1
2-24-1. Cleaner Solenoid Position
Adjustment
<Tools required>
Eccentric Driver (VFK0357)
1.
Press the iron core of Cleaner Solenoid.
2.
Observe the clearance (D) between Cleaning
Arm Unit and Cleaner Base Plate as shown in
Figure 2-24-3. And make sure that it is within 0.5
to 0.7mm.
3.
If not, loosen the 2 screws (A) as shown in Figure
2-24-2 and adjust the position of Cleaner
Solenoid Unit by moving arrow direction (C ←→
C) using the Eccentric drive so that the clearance
(D) is within the specification. And tighten the 2
screws.
4.
After adjustment, confirm that as follows.
5.
Press the iron core of Cleaner Solenoid and
released it, then the Cleaning Roller return to
original position.
6.
Press the iron core of the Cleaner Solenoid and
confirm that the Cleaner Roller rotates, when the
Cylinder is rotated by hand.
MECH-52
Figure 2-24-2