3.3
Standards and Approvals (Continued)
3.3.3 ATEX Approvals - Install per 420-0004-024-CD
Universal IV Level Transmitter – Integral
II 1 G Ex ia IIC T4 Ga -40°C ≤ Tamb ≤ +75°C; IP66 (For models
U**103**00-*-*)
II 2 G Ex d ia IIB T4 Gb -40°C ≤ Tamb ≤ +75°C; IP66 (For
models U**104**00-*-*)
II 2 D Ex tb ia IIIC Db T90°C -40°C ≤ Tamb ≤ +75°C; IP66 (For
models U**104**00-*-*)
Universal IV Level Transmitter – Remote (excluding models
U**10***00-*-*)
II 1 G Ex ia IIC T4 -40°C ≤ Tamb ≤ +75°C; IP66 (For models
U**103***0-*-*)
II 2 (1) G Ex d [ia] IIB T4 -40°C ≤ Tamb ≤ +75°C; IP66 (For
models U**104***0-*-*)
II 2 (1) D Ex tb [ia] IIIC T90°C -40°C ≤ Tamb ≤ +75°C; IP66 (For
models U**10****0-*-*)
700-*, Universal IV Sensors
II 1 G Ex ia IIC T2...T5 Ga -40°C ≤ Tamb ≤ +75°C
II 1 D Ex ia IIIC T300°C...T90°C Da -40°C ≤ Tamb ≤ +75°C
3.3.4 IECEx Approvals - Install per 420-0004-024-CD
Integral:
Ex ia IIC T4 Ga; Ex d ia IIB T4 Gb; Ex tb ia IIIC T90°C Db;
-40°C ≤ Ta ≤ +75°C; IP66
Input Voltage: 13-30Vdc; 1W
Remote:
Ex ia IIC T4 Ga; Ex tb [ia] IIIC T90°C Db; Ex d [ia] IIB T4 Gb;
Ex tb [ia] IIIC T90°C Db; -40°C ≤ Ta ≤ + 75°C; IP66
Input Voltage: 13-30Vdc; 1W
Remote Sensor:
Ex ia IIC T5 ... T2 Ga; Ex ia IIIC T90°C ... T300°C Da; -40°C ≤
Ta ≤ +75°C; IP66