6.2

Electromagnetic compatibility

Definition
Electromagnetic compatibility refers to the capability of electrical equipment of reliably
performing its dedicated function in an electromagnetic environment, without causing
interference in the same environment.
The ET 200pro distributed I/O system meets all requirements of EMC legislation for the
European market. This requires that the ET 200pro distributed I/O system complies with the
requirements and guidelines for electrical installation.
Pulse-shaped interference
The following table shows the electromagnetic compatibility of the ET 200pro distributed I/O
system relative to pulse-shaped interference.
Pulse-shaped interference
Electrostatic discharge
according to IEC 61000-4-2.
Burst pulses (high-speed transi-
ent interference) according to
IEC 61000-4-4.
High-energy single pulse (surge) according to IEC 61000-4-5
Only with lightning protection elements
Sinusoidal interference
The table below shows the electromagnetic compatibility of the ET 200pro distributed I/O
device with respect to sinusoidal interference.
80 to 1000 MHz; 1.4 to 2 GHz
10 V/m 80% AM (1 kHz)
2 to 2.7 GHz
1 V/m at 80% AM (1 kHz)
ET 200pro distributed I/O EtherNet/IP interface module
Manual, 03/2016, A5E32861915-AB
Asymmetric coupling
Symmetric coupling
HF interference according to IEC 61000-4-3
Electromagnetic HF field
Amplitude modulated
Tested with
8 kV
6 kV
2 kV (supply line)
2 kV (signal line)
2 kV (supply line)
2 kV (signal/data line)
1 kV (supply line)
1 kV (signal/data line)
0.15 to 80 MHz
10 V
rms
80% AM (1 kHz)
150 Ω source impedance
General technical specifications
6.2 Electromagnetic compatibility
Corresponds to degree
of severity
3 (air discharge)
3 (contact discharge)
HF coupling according to
IEC 61000-4-6
unmodulated
3
3
3