Opening The Cover; Closing The Cover; Standards And Approvals - Ametek Drexelbrook Universal IV CM Installation And Operating Instructions Manual

Water cut meter-density compensation with hart protocol
Table of Contents

Advertisement

Universal IV™ CM Density Compensated Model

6.2.1 Opening the cover

Procedure
1. Unscrew cover stop, if applicable
2. Unscrew terminal compartment cover

6.2.2 Closing the cover

Warning: Ex d [ia] applications
Check that the terminal compartment cover is screwed tight and the cover stop (if
applicable) is fastened tightly to the cover.
6.3

Standards and Approvals

6.3.1 FM US Approvals - Install per 420-0004-412-CD
TThe Density Compensation Module is rated as Explosionproof for Class I, Division
1, Groups C & D; Dust lgnitionproof for Class II & Ill, Division 1, Groups E-G
and Class I, Zone 1, Group lIB Hazardous (Classified) Locations with an integral
sensor that is Intrinsically Safe for Class I, II & Ill, Groups A-G and Class I, Zone
1 Hazardous (Classified) Locations. The Remote version is rated as Explosionproof
Class I, Division 1, Groups C & D; Dust-lgnitionproof for Class II & Ill, Division 1,
Groups E-G and Class I, Zone 1, Group lIB Hazardous (Classified) Locations with
connections to a 700 Series sensor that is Intrinsically Safe for Class I, II & Ill,
Groups A-G and Class I, Zone 1 Hazardous (Classified) Locations.
6.3.2 FM Canada Approvals - Install per 420-0004-412-CD
The Density Compensation Module is rated as Explosionproof for Class I, Division
1, Groups C & D; Dust lgnitionproof for Class II & Ill, Division 1, Groups E-G and
Class I, Zone 1, Group lIB Hazardous Locations with an integral sensor that is
Intrinsically Safe for Class I, II & Ill, Groups A-G and Class I, Zone 1 Hazardous
Locations. The Remote version is rated as Explosionproof Class I, Division 1, Groups
C & D; Dust-lgnitionproof for Class II & Ill, Division 1, Groups E-G and Class I,
Zone 1, Group lIB Hazardous Locations with connections to a 700 Series sensor that
is Intrinsically Safe for Class I, II & Ill, Groups A-G and Class I, Zone 1 Hazardous
Locations.Class I, Zone 1, Group lIB Hazardous Locations with connections to a
700 Series sensor that is Intrinsically Safe for Class I, II & Ill, Groups A-G and
Class I, Zone 1 Hazardous Locations.
58

Advertisement

Table of Contents
loading

Table of Contents