Water cut meter-density compensation with hart protocol
Table of Contents

Advertisement

Universal IV™ CM Density Compensated Model
5.3 Error Codes (Continued)
Table 5.2
Code
ERROR 01
ERROR 02
ERROR 03
ERROR 04
ERROR 05
ERROR 06
ERROR 07
ERROR 08
ERROR 09
ERRPR 10
ERROR 11
ERROR 12
Display Message
CALCULATION K EFF EXCEEDS
K H2O ERROR
CALCULATION EFF CAP
RANGE ERROR
CALCULATION AIR CAP RANGE
ERROR
CALCULATION EFF DENSITY
RANGE ERROR
CALCULATION H2O DENSITY
RANGE ERROR
CALCULATION OIL DENSITY
RANGE ERROR
CALCULATION TEMPERATURE
RANGE ERROR
CALCULATION K EFF RANGE
ERROR
CALCULATION K EFF RANGE
ERROR
CALCULATION FLOWRATE
THRESHOLD ERROR
FIELD FLASH CKSM ERROR
IM INTERMITTENT COMM LOSS
ERROR
Description
Calculated effective dielectric
constant exceeds water dielectric
constant
Calculated effective capacitance
is outside of expected limits
Calculated air capacitance is
outside of expected limits
Calculated effective (mixture)
density is outside of expected
limits
Calculated water density is
outside of expected limits
Calculated oil density is outside of
expected limits
Calculated temperature is outside
of expected limits
Calculated effective dielectric
constant is outside of expected
limits
Calculated water dielectric
constant is outside of expected
limits
Flow rate has dropped below
threshold. Density value is locked
on last density before threshold
drop
Field flash checksum failure Lost
customer configuration
Inter microprocessor intermittent
loss of communication
52
Actions
1. Cycle power.
2. Hardware Failure - Contact
factory
1. Calibrate DCM
2. Verify U-IV CM is operating
correctly. Reference U-IV CM
manual
3.Contact factory
1. Verify U-IV CM & Coriolis are
operating correctly.
2. Verify Cut Monitor is for the
correct pipe size.
3.Contact factory
1. Verify U-IV CM & Coriolis are
operating correctly
2.Contact factory
1. Verify U-IV CM & Coriolis are
operating correctly
2.Contact factory
1. Verify U-IV CM & Coriolis are
operating correctly
2.Contact factory
1. Verify U-IV CM & Coriolis are
operating correctly
2.Contact factory
1. Verify U-IV CM & Coriolis are
operating correctly
2.Contact factory
1. Verify U-IV CM & Coriolis are
operating correctly
2.Contact factory
1. If system is not running, no
action required
2. Verify Coriolis operating
properly
3. Consult factory
Reconfigure DCM
No Action required