Graco Therm-O-Flow 200 Instructions - Parts Manual page 75

Bulk hot melt system
Hide thumbs Also See for Therm-O-Flow 200:
Table of Contents

Advertisement

Merkur 2200, 23:1 Pump Modules
327
303
337
302
9
304
305
318
306
8
10
307
1 7
1
Torque to 50-60 ft-lbs (68-81 N•m).
2
Torque to 145-155 ft-lbs (196-210 N•m).
3
Coat mounting surface of sensor mounting block (322) with
non-silicone heat sink compound. Do not coat sensor.
4
Prior to tightening band clamp (321), RTD sensor (320)
must be fully contained within the sensor mount (322).
5
After fastening band clamp (321), secure excess with
fiberglass tape.
334130L
301
338
316
315
312
318
4
311
320
334
317
335a
2
336
335b
6
Coat inside of heater (309a, 309b) only to within 0.75 in. (19
mm) of vertical ends with non-silicone heat sink compound
before mounting.
7
Cap screws (311) must be loose while tie rods (307) are
being torqued.
8
Torque to 150 ft-lb (203 N•m).
9
Install swivel fitting (302) prior to screw (303) and reed switch
assembly (304).
10
Apply anaerobic sealant to threads.
329
308
1
310
309a
6
323
324
325
322
3
5
321
309b
6
326
333
ti25145a
Parts
75

Advertisement

Table of Contents
loading

Table of Contents