Appendix B - USB Data

The system can store 250,000 entries in its logs and the
system adds a new entry to the logs every 15 seconds.
This means the system stores 1041 hours of system
operation data, or 43 days of around-the-clock
operation. Once full, the system will overwrite the oldest
data.
NOTE: To prevent losing any data, never go more than
43 days without downloading the logs.

Download

NOTICE
Uploading an edited system configuration file can
damage the system. Never put a modified SET-
TINGS.TXT file in the UPLOAD folder on the flash
drive.
NOTE: The event log, error log, system settings, and
system language files are all downloaded in this proce-
dure.
1. Insert USB flash drive into USB port.
NOTE: Flash drive must be 8 GB or smaller.
2. The menu bar and USB indicator lights indicate that
the USB is downloading files. Wait for USB activity
to complete. A pop-up will be present until the trans-
fer is complete if it is not acknowledged.
NOTE: If the pop-up screen does not appear, the flash
drive is not compatible with the ADM. Try a different
flash drive.
NOTE: The system can log up to 45 mb of additional
data per week, depending on system operation.
334130L

Access Files

All files downloaded from the USB are put in a DOWN-
LOAD folder on the stick drive. For example:
"E:\GRACO\12345678\DOWNLOAD\". The 8-digit
numeric folder name matches the 8-digit ADM serial
number, which is located on the back of the ADM. When
downloading from multiple ADMs, there will be one
sub-folder in the GRACO folder for each ADM.
The log files should be opened in a spreadsheet pro-
gram.
NOTE: If emailing the files, zip (compress) them to mini-
mize file size.

Upload

Upload a system configuration file and/or a custom lan-
guage file. See System Settings File, page 108 or Sys-
tem Language File, page 109.
1. If necessary, follow the Download Instructions,
page 107, to automatically generate the proper
folder structure on the USB flash drive.
2. Insert USB flash drive into USB port of computer.
3. The USB flash drive window automatically opens. If
it does not, open USB flash drive from within Win-
dows Explorer.
4. Open Graco folder.
5. Open system folder. If working with more than one
system, there will be more than one folder within the
Graco folder. Each folder is labeled with the corre-
sponding serial number of the ADM. (The serial
number is on the back of the module.)
If installing the system settings file,
6.
TINGS.TXT file into UPLOAD folder.
If installing the custom language file,
7.
TEXT.TXT file into UPLOAD folder.
8. Remove USB flash drive from computer.
9. Install USB flash drive into Therm-O-Flow system
USB port.
10. The menu bar and USB indicator lights indicate that
the USB is uploading files. Wait for USB activity to
complete.
Appendix B - USB Data
place SET-
place DISP-
107

Advertisement

Table of Contents
loading

Table of Contents