Select ADM Settings
NOTE: See Appendix A - ADM, page 98 for detailed
ADM information, including general operation.
1. Turn main power switch on.
2. When the ADM is finished starting up, press
to switch from the Operation screens to the Setup
screens. Use the arrows to navigate between
screens.
3. Check system settings on the System 1 screen.
4. Set alarm levels on the System 2 screen.
334130L
5. Set primary system setpoint and setback tempera-
tures for the pump, platen, and heat zones on the
Heat-A-screens.
NOTE: Setback temperatures must be at least 20°F
(10°C) lower than the setpoint temperatures.
NOTE: To ensure accurate hose temperatures, be sure
all heated hoses have their "zone type" set to "Hose."
Hoses are only present on odd zone numbers: 1, 3, 5, 7,
9, or 11.
a. Select the appropriate "Zone Type" for all
installed zones.
b. Check the "A" and "B" boxes according to which
systems needs to use the heated accessory.
6. If a secondary system is used, set temperatures on
the Heat-B-screens.
7. Set the system date and time on the Advanced 1
screen.
Setup
23